Ras-24Ufp-E4 / Ras-24Ua-E4; Ras-24Ufpx4 / Ras -24Uax4 - Toshiba RAS-18UFHP-E4 Service Manual

Under ceiling/console type
Table of Contents

Advertisement

5-6. RAS-24UFP-E4 / RAS-24UA-E4

RAS-24UFPX4 / RAS-24UAX4
0.39m
(Connecting pipe)
∅15.88 mm
0.39m
(Flexible pipe)
P
∅15.88 mm
O.D.:15.88 mm
Packed valve
(∅15.88 )
Cooling
Compressor
PH400X3CS-4KT1
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.
Indoor unit
Evaporator
Multi blade fan
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
exchanger interchanging
pressure P
pipe T (°C)
(MPaG)
0.4
0.6
0.3
– 26 –
FILE NO. SVM-05015
T
Packed valve
(∅6.35)
Capillary tube
∅2.4x1500S
Refrigerant
R-22 1.70kg
Mark (
) means check points of Gas Leak
Fan speed
(indoor)
11.0
High
12.0
High
1.0
Low
0.49m
(Connecting pipe)
∅6.35 mm
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15