4-7. Outdoor Unit (RAS-24UAH-E4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcontroller
10
Varistor (R73, R74, R86)
11
Fuse (F01)

4-8. Outdoor Unit (RAS-24UA-E4, RAS-24UAX4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
2JS386D5BB02
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
KFG6-71SB5P-T1 Winding resistance (Ω)
(at 20°C)
451355L
AC 450 V, 3.5µF
BUM44X6005C
AC 440 V, 60µF
VHV (STF)
AC 220 – 240 V
TE / TD
10 kΩ at 25°C / 50 kΩ at 25°C
220 − 240 V, 50 Hz
A35
TT-05
220 – 240 V
TMP47C840N
15G471K
470 V
MT3
T6.3 A, 250 V
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
PH400X3CS-4KT1 Winding resistance (Ω )
(at 20 °C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 − 240 V, 50 Hz
Winding resistance (Ω )
KFG6-71SB5P-T
(at 20 °C)
AC 450 V, 3.5µF
451355L
AC 440 V, 45µF
BUM44X4505B
220 − 240 V, 50 Hz
A35
– 19 –
FILE NO. SVM-05015
Specifications
C-R
0.886
Red-Black
White-Black
64.4
Specifications
C-R
1.13
Red-Black
White-Black
64.4
C-S
1.979
127.4
C-S
2.10
127.4