10-4 Outdoor Unit (RAS-18UA-E4, RAS-18UAX4, RAS-18UA-AR4)
No.
Part name
1
Common
procedure
Running
2
capacitor
for compressor
Running
3
capacitor
f or fan motor
Magnetic contactor
4
5
Spark killer
Procedures
1) Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
2) Remove the packed valved cover and the electrical
(3 screws ∅ 4 x 10L)
Parts cover
3) Remove 2 cord clamps (4 screws ∅ 4 x 22L) and
disconnect the power supply cord and connecting
cable after removing 6 screws on the terminal block
and 1 ground screw on the electrical parts base.
4) Remove the upper cabinet. (4 scerws ∅ 4 x 10L)
(Pulling out upward)
5) Remove the front cabinet. (3 screws ∅ 4 x 10L)
(Pull the front right protion toward you, and remove
it pulling out upward.)
1) Perform the common procedure 1
2) Remove the capacitor band. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅ 4 x 10L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅ 4 x 10L)
3) Disconnect the lead wires from the terminal.
Packed valve cover
Running capacitor
for compressor
Magnetic
contactor
− 84 −
FILE NO. SVM-05015
Remarks
Electric
parts cover
2 Cord clamps
3 - screws ∅ 4 x 10L
4 - screws ∅4 x 22L
Upper
cabinet
Front
cabinet
Running capacitor
for fan motor
Spark killer