Lincoln Electric SVM138-A Service Manual page 119

Wire feeder
Table of Contents

Advertisement

F-55
DIGITAL METER AND METER PC BOARD REMOVAL AND
METER PC BOARD REMOVAL
PROCEDURE
1. Remove input power to the LN-9 GMA Wire
Feeder.
METER
3. Lift the right side cover assembly.
TROUBLESHOOTING & REPAIR
REPLACEMENT (continued)
FIGURE F.13 – METER PANEL ASSEMBLY SCREWS
MOUNTING SCREWS
FIGURE F.14 – METER REMOVAL (WITH SHORT LEADS)
LN-9 GMA Wire Feeder
2. Locate and remove the two screws on the top
left and right side of the meter panel assem-
bly. See Figure F.13.
4. Carefully remove the meter enclosure panel.
Note the limited lead length. See Figure F.14.