Wire Reel Dust Shield For K376 50 To 60 Lb Wire Reel Mounting Stand; Wire Reel Dust Shield Door For K303 And K376; Or 10 To 30 Lb Spools With 2 In. I.d; K378 Small Mounting Stand For 13 To 14 Lb Innershield Coils - Lincoln Electric SVM 106-A Service Manual

Wire feeder
Table of Contents

Advertisement

ACCESSORIES
WIRE REEL DUST SHIELD
FOR K376 50 TO 60 LB WIRE
REEL MOUNTING STAND
A shield is available to cover the wire and
reel to protect the wire from falling dirt and
dust. Order part no. S-14543. Instructions
are provided with the kit.
WIRE REEL DUST SHIELD
DOOR FOR K303 AND K376
In extremely dusty and dirty locations this
door kit can be added to those units having
the dust shield kit (S-14543). This door kit
includes a hinged door and sliding bottom
seal. When these parts are attached to the
reel support per the instructions included, the
unit becomes a completely enclosed
housing. Order part no. M11514.
K377
SMALL
STAND
FOR
READ-REEL
COILS OR 10 TO
SPOOLS WITH 2 IN. I.D.
This assembly includes a wire reel spindle
(similar to the K162 spindle) attached to a
small frame. The unit is supplied with the
K363 Readi-Reel Adapter for using the
Lincoln
"Readi-Reel
Electrode
Without the adapter the unit is capable of
handling spools with a 2 in. I.D., a 12 in.
maximum O.D., and a 4 in. width. For spools
with an 8 in. O.D., a K468 spindle adapter is
available. The spindle has an adjustable
braking system. See Attaching the Wire Reel
Stand procedure at the end of this section for
installation procedures.
K378
SMALL
STAND FOR 13 TO 14 LB
INNERSHIELD COILS
This assembly includes the same smaller
frame as used in the K377 and the fully
enclosed canister system for dereeling of the
14 lb coil. This system has a fixed brake for
the 14 lb coil. See Attaching the Wire Reel
Stand Procedure at the end of this section
for installation procedures.
K292 POWER INPUT
EXTENSION CABLE
(600 AMPS)
Can be used to a maximum of 400 ft (122 m).
See Input Cable Connections section in the
Installation Section for a description of this
cable.

POWER INPUT CABLES

A variety of power input cable assemblies
are available for various current ratings and
power source connection types. All provide a
polarized control cable plug (MS-3106A-18-
MOUNTING
12S) and a lugged electrode cable for con-
nection to the wire feeder.
30 LB

K291 INPUT CABLE

The K291 input cable assembly consists of
a six-conductor control cable and a 3/0
(85 mm
amps, 60% duty cycle and is available in
Coils".
lengths of 10, 25, 50, 75, and 100 feet (3.0,
7.6, 15.2, 22.9, and 30.4 m).

K404 INPUT CABLE

The K404 input cable is similar to the K291
but includes a 1/0 (53 mm
It is rated at 350 amps, 60% duty cycle. It is
available in lengths of 10, 25, and 50 feet
(3.0, 7.6, and 15.2 m). These control cables
have lugged leads for power sources with
MOUNTING
stud output terminals and terminal strip
control lead connections.
2
) electrode cable. It is rated at 600
2
) electrode cable.
LN-7 GMA WIRE FEEDER
C-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ln-7 gma

Table of Contents