Lincoln Electric RANGER SVM120-A Service Manual page 74

Lincoln electric welder user manual
Table of Contents

Advertisement

F-20
TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
The welding arc is "cold."
engine runs normally (3700 RPM
no load).
The auxiliary power is
functioning normally.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.
TROUBLESHOOTING & REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
WELDING PROBLEMS
The
1. Check for loose or faulty con-
nections at the weld output ter-
minals and welding cable con-
nections.
2. The welding cables may be too
long or coiled, causing an
excessive voltage drop.
CAUTION
RANGER 10-LX
Observe Safety Guidelines
detailed in the beginning of this manual.
RECOMMENDED
COURSE OF ACTION
1. Check for the correct open cir-
cuit voltage (OCV) at the weld-
ing output terminals. If the cor-
rect voltage is present at the
output terminals, then check for
loose connections on the heavy
current carrying leads inside the
RANGER 10-LX. See Wiring
Diagram.
2. If the OCV is low at the welder
output terminals, perform the
Engine Throttle Adjustment
Test.
3. Perform the Output Rectifier
Bridge Test.
4. Check for shorted or grounded
windings in the reactor and also
in the main stator. See Wiring
Diagram.
F-20