Normal Open Circuit Voltage Waveform (120 Vac Supply - Lincoln Electric RANGER 250 SVM150-A Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-45
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (120VAC SUPPLY)
TROUBLESHOOTING & REPAIR
HIGH IDLE – NO LOAD
16.2 ms
50V
This is the typical auxiliary output
voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.
NOTE: Scope probes are connected
at machine 120 VAC receptacle.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
RANGER 250
0 volts
5ms
F-45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ranger 250

Table of Contents