  • Page 1 TACO BELL TORTILLA WARMERS MODEL FGDLTBA FGILTBA FGTBA Installation and Operation Instructions 2M-Z9767 Rev. C 5/9/07 (FGTBA) FGDLTB (FGDLTBA) (FGILTBA)
  • Page 2: Safety Symbol

    RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability. Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
  • Page 3 SPECIFICATIONS FGILTBA Type: InLine Tortilla Warmer 650 watts, 08V, 7.9 amps 650 watts, 40V, 6.9 amps Dimensions: 5” - Width, 0.75” - Depth, .75” - Height (48.9 cm - Width, 5.7 cm - Depth, 7 cm - Height) Platen Area: .5” Width x 0” Depth (59.7 cm - Width x 50.8 cm - Depth) FGDLTBA Type: DualLine Tortilla Warmer 00 watts, 08V, 5.9 amps 00 watts, 40V, .75 amps Dimensions: 40” - Width, 5” - Depth, .75” - Height (0.6 cm - Width, 6.5 cm - Depth, 7 cm - Height) Platen Area: 40” Width x 5” Depth (0.6 cm - Width x 6.5 cm - Depth) FGTBA Type: Counter Top Tortilla Warmer 650 watts, 08V, 7.9 amps 650 watts, 40V, 6.9 amps Dimensions: 5” - Width, 0.75” - Depth, 6.5” - Height (6.5 cm - Width, 5.7 cm - Depth, 6.5 cm - Height) Platen Area: .5” Width x 0” Depth (59.7 cm - Width x 50.8 cm - Depth)
  • Page 4: Installation

    For your protection we recommend that a qualified electrician install this warmer and should be familiar with electrical installations and all electric codes. Proper connections and power supply are essential for efficient performance. The external wiring should be in conduit or an approved type of flexible cable suitable for operation at the temperature indicated on the wiring diagram, and of a proper size to carry the load. The supply circuit should be properly fused and equipped with a means of disconnecting, as required by local electrical code. Minimum clearances to stainless steel counter. (FGILTBA & FGDLTBA) Sides: /4” Bottom: 8” CONNECTING POWER SUPPLY (FGILTBA & FGDLTBA) There are pigtail leads for the supply connection located at the rear or side of the unit. All...
  • Page 5 INITIAL START UP Before using the unit for the first time, wipe down the exterior and platen area with a damp cloth. Heat for approximately 0 minutes. The warmer may emit a small amount of smoke as the cooking surfaces reaches its operating temperature. Do not be alarmed, as the smoke is caused by oils associated with the manufacturing process and will stop when the burn off is complete. Brush off any debris from the warming surface. SEASONING THE TORTILLA WARMER HEATING SURFACE For current procedures on seasoning your warmer or re-seasoning your warmer, refer to your corporate guidelines for proper methods. All heating surfaces must be properly seasoned prior to its initial use. Even with careful seasoning, food may, to some extent, stick to the warmer heating surface until the platen is broken in. TEMPERATURE CONTROL The temperature controls are preset at the factory for a 45°F average platen / heating surface temperature. The thermostat cycle will cause the platen / heating surface temperature to vary +/-0°F during normal use. PLATEN AND SHEET METAL SURFACES ARE HOT DURING OPERATION AND CAN CAUSE BURNS. CARE MUST BE TAKEN WHEN USING THIS EQUIPMENT. CAUTION WARMING OPERATION Turn the unit on and allow to pre-heat for 0 minutes prior to using. After the pre-heating period, the thermostat will automatically maintain the preset temperature. WARMING SURFACE CARE For specific instructions on the day to day care of the unit, refer to your corporate guidelines.
  • Page 6 LIMITED EQUIPMENT WARRANTY All workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies.
  • Page 10 Nameplate MODEL: FGDLTBA STAR MANUFACTURING INTERNATIONAL INC. THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC. SK2195 Rev. - 5/18/2006 NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
  • Page 11: Parts List

    PARTS LIST May 9, 007, Rev. C TACO BELL TORTILLA WARMERS FGDLTBA, FGILTBA MODEL Number Part Number Number Description and Model Designation Unit INLINE (FGILTBA) F-Z859 PLATEN FGILTBA N-Z8574 ELEMENT 85W/08V FGILTBA N-Z007 ELEMENT 85W/40V FGILTBA D6-Z876 BRACKET, ELEMENTS FGILTBA T-Z8580 THERMOSTAT TOD 49T 450°F FGILTBA T-Z9647 THERMAL CUT-OFF 98°C, 58°F FGILTBA H-Z8586 INSULATION 40 X 5 FGILTBA D6-FG0008 HOUSING ASSEMBLY FGILTBA A-Z97 BURN GUARD FGILTBA...
  • Page 12 Nameplate MODEL: FGTBA STAR MANUFACTURING INTERNATIONAL INC. THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC. SK2196 Rev. A 10/19/2006 NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
  • Page 13 COVER, T-STAT FGTBA A-Z594 FOOT, /- X 4”L FGTBA D6-Z8740 HOUSING CONTROL FGTBA E-Z897 SWITCH 5A, 50V FGTBA D6-FG0004 CONTROL PANEL ASSY FGTBA M-Z874 LABEL ON-OFF FGTBA Z-70-07-04 GUARD SWITCH FGTBA I-05-07-00 BOOT-SWITCH FGTBA J-Z9 PILOT LIGHT FGTBA K-Y6764 BUSHING - POWER CORD FGTBA D5-FG0005 POWER CORD ASSEMBLY FGTBA IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE INCLUDE MODEL AND SERIAL NUMBER OF Some items are included for illustrative purposes only and in certain instances may not be available. Star Manufacturing International, Inc.
  • Page 16 STAR MANUFACTURING 10 Sunnen Drive, St. Louis, MO 63143 U.S.A. (800) 807-9054 (314) 781-2777 Parts & Service (800) 807-9054 www.star-mfg.com...