CONTROL BOX/WIRE DRIVE ERROR CODE CHART (Continued)
Err 100
Err 200
Err 201
Err 210
Err 211
- - - (three dashes)
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
-----------------------------------------------------------------------------------------------------------------------------
TROUBLESHOOTING AND REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
For some reason the Power Wave
455 issued a shutdown command.
No response from the Power Wave
455.
No response from either the
Control Box or wire feed unit.
EEPROM error
A microprocessor RAM error
occurred in the Control Box.
Appears on the control box display.
CAUTION
POWER WAVE 455/POWER FEED 10
RECOMMENDED
COURSE OF ACTION
See Err 006 in this chart.
See Err 006 in this chart.
If this condition occurs while weld-
ing, the status LED should be flash-
ing red on the problem unit.
Otherwise, check for any units that
are flashing green. This indicates
that the particular unit has not been
recognized and there is a power
source problem. See Power Wave
455 Troubleshooting . If the STA-
TUS LED is either flashing red or
steady red, there may be a fault in
the control cable(s).
The parameter(s) recalled at power
up was out of range. Rotate
Encoder Knob to reset. Check all
settings before proceeding to weld.
If this condition persists, replace
the Control Box control board.
Remove the input power. Wait five
seconds. Turn power on. If Err
211 is displayed again, the Control
Box control board may be faulty.
This is an indication that constant
current such as STICK or GOUGE
mode has been selected. Turning
the right encoder clockwise when in
this state will activate output from
the Power Wave 455. Turning the
right encoder counterclockwise will
deactivate output.