300
WFS
AMPS
VOLTS
Less
More
Less
WFS
WFS
Volts
WELD MODE
PROCESS
GMAW, STANDARD CV
GMAW, POWER MODE
FCAW, STANDARD CV
WAVEFORM CONTROL TECHNOLOGY
IR PORT
STD CV MIG
WELD MODE
ARC CONTROL
ARC CONTROL
EFFECT / RANGE
DESCRIPTION
PINCH
Pinch controls the arc characte-
(Soft)-10.0 to
-ristics when short-arc welding.
(Crisp)+10.
0
25.3
TRIM
More
Volts
WELD MODE
5
40
6
5
SETUP
START OPTIONS
END OPTIONS
SET
250
WFS
AMPS
Less
More
WFS
WFS
START OPTIONS
EFFECT / RANGE
DESCRIPTION
Preflow Time
Adjusts the time that shielding gas
0 - 10 seconds
flows after the trigger is pulled
and prior to feeding wire.
Run-In WFS:
Run-In sets the wire feed
Off, 50 to150 in/min.
speed from the time the trigger
is pulled until an arc is estab-
lished.
Start Procedure
The Start Procedure controls
0 - 10 seconds
the WFS and Volts for a speci-
fied time at the beginning of
the weld. During the start time,
the machine will ramp up or
down from the Start Procedure
to
the
Procedure.
END OPTIONS
EFFECT / RANGE
DESCRIPTION
Postflow Time
Adjusts the time that shielding
0 to 10 seconds
gas flows after the welding out-
put turns off.
Crater Procedure
Crater Procedure controls the
0 TO 10.0 SECONDS
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.
Burnback:
The burnback time is the
0 to .25 Seconds
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
54
VOLTS
TRIM
Shorter
Longer
Arc
Arc
preset
Welding

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power feed 10m