Status Led; Digital Meters And Output Encoder Knobs - Lincoln Electric POWER FEED IM915 Operator's Manual

Single wire feeder
Table of Contents

Advertisement

b-5

1. STATUS LED

The status LED indicates system status. Normal
operation is a steady green light.
Note: During normal power-up, the LED may flash
red and/or green as the equipment performs self tests.
LED condition Definition
Steady green System okay. The power source and
wire feeder are communicating nor-
mally.
blinking green Occurs during a reset and indicates
the power source is identifying each
component in the system. This is nor-
mal for the first 10 seconds after
power-up, or if the system configura-
tion is changed during operation.
Alternating
Non-recoverable system fault. If the
green and red power source or wire feeder status
LED is flashing any combination of
red and green, errors are present in
the system. Read the error code
before the machine is turned off.
Instructions for reading the error code
are detailed in the Service Manual.
Individual code digits are flashed in
red with a long pause between digits.
If more than one code is present, the
codes will be separated by a green
light.
To clear the error, turn the power
source OFF, and then back ON to
reset. See troubleshooting section.
Steady red
Non recoverable hardware fault.
Generally indicates a problem with
the cables connecting the wire feeder
to the power source.
blinking red
Not applicable.
2. DIGITAL METERS AND OUTPUT
ENCODER KNObS
(See Figure B.2)
The primary weld procedure settings are controlled
and displayed using digital meters and output encoder
knobs located at the top of the Power Feed™ 10M
Single Wire Feeder control panel.
OPERATION
A
B
AMPS
WFS
400
TRIM
VOLTS
263
POWER FEED™ 10M SINGLE WIRE FEEDER
FIGURE b.2
A. WIRE FEED SPEED/AMMETER DISPLAY
A
400
WFS
AMPS
This meter displays either the wire feed speed or cur-
rent value (Amps) depending upon welding process
(Mode) being used and the status of the wire feeder
and power source. Written below the display is "WFS"
and "Amps". An LED light illuminates which value is
being displayed on the meter. The knob below the
meter adjusts the value displayed on the meters.
Prior to Welding
CV Welding Processes Meter displays the preset
CC Welding Processes Meter displays the preset
During Welding
An Weld Processes
After Welding
An Weld Processes
Note: If the output knob for the WFS/AMPS is adjust-
ed while the Power Feed™ 10M Single Wire Feeder is
in the "Hold" period, the Power Feed™ 10M Single
Wire Feeder will immediately revert to the "Prior to
Welding" display.
The default wire feed speed units are inches/minute and
can be changed to meters/minute by entering the "Set-up
Menu" in this Operation Section. The wire feed speed is
calibrated to within ±2%. Refer to the power source man-
ual for calibration specifications of the ammeter.
b-5
B
263
VOLTS
TRIM
Description
WFS value.
Amps.
Meter displays displays the
actual average welding
Amps.
The meter holds the actual
current value for 5 sec-
onds. The display blinks to
indicate the Power Feed™
10M Single Wire Feeder is
in the "Hold" period. If the
output is adjusted while in
the "Hold" period, the
Power Feed™ 10M Single
Wire Feeder will revert to
the "Prior to welding" dis-
play described above.