Lincoln Electric POWER FEED IM915 Operator's Manual page 47

Single wire feeder
Table of Contents

Advertisement

b-25
MACHINE FUNCTIONALITY bY WELD PROCESS
CV GMAW/FCAW (NON-SYNERGIC)
Use the following tables to review how the machine functions (output controls, arc control, Start options and weld
options) for the weld modes listed in the top table.
OUTPUT CONTROL KNObS, WELD MODE 5 & 6
300
WFS
LESS
WFS
CV NON-SYNERGIC MODES
Material
Steel
Steel
GMAW, POWER MODE
Steel
WAVEFORM CONTROL TECHNOLOGY
IR PORT
WELD MODE
ARC CONTROL
5
WAVEFORM CONTROL TECHNOLOGY
STD CV MIG
IR PORT
SETUP
ARC CONTROL
WELD MODE
SET
END OPTIONS
START OPTIONS
ARC CONTROL
25.3
300
VOLTS
WFS AMPS
TRIM
VOLTS
LESS
MORE
WFS
WFS
LESS
VOLTS
MORE
EFFECT / RANGE
(Soft)-10.0 to
(Crisp)+10.0
25.3
AMPS
VOLTS
TRIM
MORE
LESS
MORE
WFS
VOLTS
VOLTS
PROCESS
WELD MODE
GMAW, CV
FCAW, CV
5
SETUP
STD CV MIG
START OPTIONS
END OPTIONS
SET
DESCRIPTION
Arc Force adjusts the short cir-
cuit current for a soft arc, or for
a forceful, digging arc.
POWER FEED™ 10M SINGLE WIRE FEEDER
OPERATION
OUTPUT CONTROL KNObS, WELD MODE 40
LESS
WFS
START OPTIONS
The start Options available in these Non-Synergic CV weld
modes, their adjustment range and function are as follows:
EFFECT / RANGE
Preflow Time
5
0 to 25.0 seconds
40
6
Run-In WFS:
Off, 30 to150 in/min.
Start Procedure
0 to 10 seconds
WFS
MORE
200
LESS
WFS AMPS
WFS
ARC
TRIM
LONGER
ARC
VOLTS
2.0
SHORTER
END OPTIONS
EFFECT / RANGE
Spot Timer:
0 to 120.0 Seconds
Postflow Time
0 to 25.0 seconds
Crater Procedure
(0 TO 10.0 SECONDS)
Burnback:
0 to .25 Seconds
200
2.0
WFS
AMPS
VOLTS
MORE
SHORTER
WFS
ARC
DESCRIPTION
Adjusts the time the gas flows
after the trigger is pulled and
prior to feeding.
Run-In sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.
The Start Procedure controls the
WFS and Volts for a specified time
at the beginning of the weld.
During the start time, the machine
will ramp up or down from the
Start Procedure to the preset
Welding Procedure.
DESCRIPTION
Adjusts the time welding will continue
even if tigger is still pulled. This option
has no effect in 4-Step Trigger Mode.
Adjusts the time that shielding gas
flows after the welding output turns off.
Crater Procedure controls the WFS
and Volts for a specified time at the
end of the weld after the trigger is
released. During the Crater time, the
machine will ramp up or down from the
Weld Procedure to the Crater
Procedure.
The burnback time is the amount of
time that the weld output continues
after the wire stops feeding. It prevents
the wire from sticking in the puddle and
prepares the end of the wire for the
next arc start.
b-25