DIP SWITCH SETUP

SETTING
DIP
SWITCHES
CONTROL BOX
There are two DIP switch banks on the mother board
of the Control Box. They are labeled S1 and S2 and
are located and oriented as shown in Figure A.3.
S2 DIP Switch Bank on Control Box Motherboard (For software version S24004-2 only)
Switch
Off
1
Network Group ID, MSB (Assigns Control Box to a specific group) (Off is factory setting)
2
Network Group ID, LSB (Assigns Control Box to a specific group ) (Off is factory setting)
3
Spare
4
Spare
5
Spare
6
Spare
7
Spare
8
Reserved
S1 DIP Switch Bank on Control Box Motherboard (For software version S24004-3 & up)
Switch
Off
1
Standard speed gearbox limits adjustable
2
WFS Display = inches/minute
3
Left Display is always preset WFS
CC modes override this switch regardless of position. Left Display is always preset weld cur-
rent when weld current is not flowing and actual weld current when weld current is flowing
4
Run-in = Minimum Speed Available
If any option containing a Run-in setting is connected to the motherboard, it automatically
overrides this switch regardless of position.
5
Memory change with trigger disabled
6
Acceleration, MSB (Sets acceleration rate for wire drive) see below
7
Acceleration
8
Acceleration, LSB
Note: the factory shipped settings for all of the S1 and S2 switches is "OFF".
INSTALLATION
IN
THE
On
On
High speed gearbox limits adjustable
WFS Display = meters/minute
Left Display is preset WFS when weld current is not flowing
Left Display is actual weld current when weld current is flowing
Run-in = weld WFS
Memory change with trigger enabled
(Sets acceleration rate for wire drive) see below
(Sets acceleration rate for wire drive) see below
POWER FEED 10
S1
ON
1
2
3
4
5
6
7
8
ON
S2
1
2
3
4
5
6
7
8
FIGURE A.3
A-7