DIP SWITCH DESCRIPTIONS 
 
OPTIMARC®
CV/CC machine offers a DIP switch on the 
control board, which allows user to have additional 
features. After disconnecting the machine from input 
power remove the roof To set the DIP switch.See 
FIGURE B.7 for the right position.  
There are 8 individual switches integrated into this DIP 
switch .All the initial factory settings in the OFF 
position. Please see FIGURE B.6. 
 
    WARNING 
 
Disconnecting the power 
supply  
before the roof removed. 
 
 
 
1. PREFLOW ON/OFF SWITCH 
This switch enables preflow before turning on output 
voltage. Please see FIGURE B.3 for detail.  
 
2. LONG CABLE WELD  MODE SWITCH  
OFF = welding with a cable length less than 20M. 
ON = welding with a cable length more than 20M 
(including 20M). 
 
3. CRATER REPEAT MODE SWITCH 
After releasing the trigger, if the operator find a 
visible crater appearing, and activating the trigger 
again within 2 seconds, the power source will 
continue output at crater voltage and current to fill 
this crater. For more details, please see FIGURE B.5. 
 
 
 
 
OPERATION
                                                                                               
4. SPECIAL FUNCTION TEST 
It enables a test procedure to test the control knobs 
and the toggle switches when this DIP switch is ON 
and the other DIP switches are OFF. This DIP switch 
should be OFF when user prepares to weld. 
 
5. SYNERGIC 
OFF = Amps and volts knobs on feeder are 
independent. 
ON = Preset of volts knob is tied to the preset of the 
amps knob. 
Set the current first, then set the voltage to match 
 
the current, such as 200A/25V, then the voltage will 
follow the current as machine programmed when 
the current adjusted. 
See operation feature item 8. 
 
6. FAST RUN‐IN 
OFF = run‐in speed is 35% of weld set wire feed 
speed (limited by the absolute wire feed speed 
minimum set in the parameter file) 
ON = run‐in speed is 75% of weld set wire feed speed 
(limited by the absolute wire feed speed minimum 
set in the parameter file) 
 
7. FEEDER APPLICATION 
OFF = 18.3V wire feeder application. 
ON = 24V wire feeder application. 
 
8. WIRE FEEDER SPEED CALIBRATION 
 
 
FIGURE B.6 – DIP SWITCH LOCATION 
®
OPTIMARC
CV/CC500
B‐6 