Error Display - Denon AVR-3311CI Service Manual

Av surround receiver
Hide thumbs Also See for AVR-3311CI:
Table of Contents

Advertisement

1.3. Error display

See the following table for each "Error information" display and its contents (status).
Display order is q , w , e , r , t .
Condition
q Sub-μcom NG No response from Sub-μcom
w DIR NG
No response from DIR
When DSP boot, executing DSP reset makes no change to DSP1 FLAG0
port "H".
No change to DSP FLAG0 port "H" before issuing DSP command.
When DSP data read, executing WRITE="L" makes no change to ACK="H".
When DSP data read, executing REQ="L" makes no change to ACK="L".
When DSP data write, executing WRITE="H" makes no change to ACK="H".
e DSP NG
When DSP data write, executing REQ="L" makes no change to ACK="L".
When DSP special code boot, executing DSP reset makes no change to
DSP FLAG0 port "H".
No change to DSP FLAG0 port "H" before issuing DSP special read
command.
No change to DSP FLAG0 port "H" before DSP version read.
r EEPROM NG
Error appeared in EEPROM checksum.(*** is a block address number.)
t B oth SUB/DSP
/EEPROM OK
State
18
State
S U B
E R R O R
D I R
E R R O R
D S P
E R R O R
D S P
E R R O R
D S P
E R R O R
D S P
E R R O R
D S P
E R R O R
D S P
E R R O R
D S P
E R R O R
D S P
E R R O R
D S P
E R R O R
E 2 P R O M
E R R * * *
(No error display, version display only)
0 1
0 1
0 1
0 2
0 3
0 4
0 5
0 6
1 1
1 2
1 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avr-3311

Table of Contents