REQUIRED TOOLS AND MATERIALS
INSTALLATION
THE BASIC REVERSE OSMOSIS SYSTEM
•
Adjustable wrench, and larger adjustable jaw pliers or pipe wrench
to fit sink drain
•
Saw for cutting drain pipe
•
Slotted and Phillips head screwdrivers
•
Tubing cutters
•
Electric drill and bits for cutting the faucet mounting hole
Note that some sinks will have a pre-drilled hole with a plug for the
faucet.
STEP 1: Install cold water supply valve
STEP 2: Install drain adapter
STEP 3: Install faucet
STEP 4: Make tubing connections
STEP 5: Install RO assembly
STEP 6: Put system into operation
NOTE: Consult a licensed plumber if you are not familiar with
plumbing procedures.
STEP 1: INSTALL COLD WATER SUPPLY VALVE
Comply with local plumbing codes. A typical connection using a water
supply valve is shown. The feed water valve is not included with
system. Contact supplier for this item.
Water Supply Valve
NOTE: Be sure to turn off the water supply and open a low faucet to
drain the pipe.
Cold water pipes vary in size and style. The installer will determine
type of valve that will be used. Install a valve on the cold water supply
pipe to adapt 1/2-inch OD tubing. If threaded fittings are used, be sure
to use pipe joint compound or Teflon tape on outside threads.
Turn the valve off.
9