Troubleshooting - Landa MPE5-50024B Operator's Manual

Table of Contents

Advertisement

PROBLEM
PUMP RUNNING
NORMALLY BUT
PRESSURE LOW
ON INSTALLATION
FLUCTUATING
PRESSURE
PRESSURE LOW
AFTER PERIOD OF
NORMAL USE
PUMP NOISY
PRESENCE OF WATER
IN PUMP OIL
WATER DRIPPING
FROM UNDER PUMP
WATER DRIPPING
FROM PUMP
PROTECTOR
OIL DRIPPING
EXCESSIVE VIBRATION
IN HIGH-PRESSURE
HOSE

TROUBLESHOOTING

POSSIBLE CAUSE
Pump sucking air
Check valves sticking
Unloader valve seat faulty
Nozzle incorrectly sized
Worn piston packing
Valves worn
Blockage in valve
Faulty or misadjusted
unloader valve
Pump sucking air
Worn piston packing
Insuffi cient water
Nozzle worn
Suction or delivery valves worn
Suction or delivery valves blocked
Unloader valve seat worn
Worn piston package
Air in suction line
Broken or weak suction or delivery
valve spring
Foreign matter in valves
Worn bearings
Excessive temperature of water
Oil seal worn
High humidity in air
Piston packing worn
Piston packing worn
O-Ring plunger retainer worn
Water supply pressure too high
(over 90 psi)
Spray gun is in the off position for
over 1-2 minutes
Oil seal worn
Irregular functioning of the pump
valves
8.914-000.0 • 8.917-410.0 • 9.800-340.0 • 8.919-014.0 • Rev. 06/12
SOLUTION
Check water supply and possibility of air
seepage.
Check and clean or replace if necessary.
Check and replace if necessary.
Check and replace if necessary.
Check and replace if necessary.
Check and replace if necessary.
Check and clean out if necessary.
Tampering with the factory setting may
cause personal injury and/or property
damage, and will void the
manufacturer's warranty.
Check water supply connections.
Check and replace if necessary.
Check fi lter and hose for breakage.
Check and replace if necessary.
Check and replace if necessary.
Check and clean if necessary.
Check and replace if necessary.
Check and replace if necessary.
Check water supply and connections on
suction line.
Check and replace if necessary.
Check and clean if necessary.
Check and replace if necessary.
Reduce to below 140°F.
Check and replace if necessary.
Check and change oil twice as often.
Check and replace if necessary.
Check and replace if necessary.
Check and replace if necessary.
Lower water supply pressure using a
regulator.
Turn machine off if not in use for over 1-2
minutes.
Check and replace if necessary.
Check and replace if necessary
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpe5-50024cMpe

Table of Contents