Lincoln Electric INVERTEC POWER WAVE IM542-D Operator's Manual page 27

Lincoln electric welder user manual
Table of Contents

Advertisement

B-11
3. PROGRAM LIST: The PROGRAM LIST block in
the center of this overlay provides a convenient
place to record a brief description of each welding
procedure stored in memory. A "Dry Erase" mark-
er should be used for this purpose.
4. DISPLAY RECALL KEY: To view other information
about the selected procedure, press the DISPLAY
RECALL key. The display window will show the
procedure description and gas type of the se-
lected procedure for as long as the key is held
depressed. When the key is released, material
type, wire size, and process descriptions will be
displayed for a few seconds.
5. HIGH TEMPERATURE LIGHT: The high tempera-
ture light comes on when the internal machine
temperature exceeds the allowed limit. Output is
disabled until the machine cools down and the
high temperature light goes out.
6. MEMORY LIGHTS: A memory light is on when its
corresponding memory is selected. This tells you
what memory is active at any given time.
7. TOUCH SENSE LED: This light comes on during
the touch sensing sequence when a touch sensing
robot controller is used
OPERATION
POWER WAVE 450
B-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec power wave 450 robotic

Table of Contents