Desa VUL18NR Owner's Operation And Installation Manual page 23

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

LIGHTING
INSTRUCTIONS
WARNING:
• If fireplace has glass doors,
never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Make
sure there are no obstructions
across openings of fireplace.
• You must operate this heater
with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open damper or window to
vent smell. This will only last a
few hours.
Note: Home owners generally prefer to operate
their heater with the chimney damper closed.
This will put all the heat into the room. However,
there may be times you will desire the full flames
of the HI heat setting but will find the heat output
excessive. You can open the chimney damper (if
you have one) fully or partially to release some
of the heat.
WARNING: Damper handle
will be hot if heater has been
running.
1. STOP! Read the safety information,
page 22.
2. Make sure equipment shutoff valve is
fully open.
3. Set selector switch in the OFF position.
4. Press in and turn control knob clock-
wise
to the OFF position (see
Figure 32).
122001-01C
OPERATION
REMOTE-READy MODELS
www.desatech.com
Continued
WARNING: burners will come
on automatically within one minute
when the selector switch is in the
ON position after the pilot is lit.
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow B
in the safety information, page 22. If you
don't smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
Press in control knob for five (5) seconds
(see Figure 32).
Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or less.
This will allow air to bleed from the gas
system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 24.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise
Control Knob
Flame
Ignitor
Adjustment
Button
Knob
Figure 32- Control Knob and Ignitor
Button Location
to the PILOT position.
to the ON position.
ON
OFF
REMOTE
Selector Switch
in OFF Position
23