Desa VUL18NR Owner's Operation And Installation Manual page 12

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

Determining Minimum Mantel Clearance
When Using a Hood
If minimum clearances in Figure 6, page 11, are
not met, you must have a hood. When using
a hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7, when using hood.
NOTICE: Surface temperatures
of adjacent walls and mantels
become hot during operation.
Walls and mantels above the
firebox may become hot to
the touch. If installed properly,
these temperatures meet the
requirement of the national
product standard. Follow all
minimum clearances shown in
this manual.
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel
12"
10"
8"
6"
2
1 /2
"
Minimum
Noncombustible
Material
Hood
(GA6050,
GA6052,
or GA6053)
Figure 7 - Minimum Mantel Clearances
When Using Hood
12
INSTALLATION
Mantel Shelf
Underside of
Mantel Shelf
All minimum
distances are
in inches
8"
12"
15"
18"
20"
Min.
Distances to
Underside of
Mantel
www.desatech.com
Continued
FLOOR CLEARANCES
A. If installing appliance on the floor level,
you must maintain the minimum distance
of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14"
to the fireplace, you must install appliance
at least 5" above the combustible flooring
(see Figure 9).
Figure 8 - Minimum Fireplace Clearances
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
Note: When used as a vented heater, ap-
pliance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of noncombustible material.
For Massachusetts Residents Only: Instal-
Log Sets
18", 24",
lation of this gas log set as a vented appliance
30" & 36"
Models
in the Commonwealth of Massachusetts re-
Top of
quires the damper be permanently removed
Fireplace
or welded in the fully open position.
Opening
If your heater is a manually-controlled model,
you may use this heater as a vented product.
There are three reasons for operating your
heater in the vented mode.
1. The fireplace does not meet the clearance
to combustibles requirements for vent-
free operation.
14"
Min.
Noncombustible Material
If Installed at Floor Level
Hearth
5"
Min.
Combustible
Material
Combustible
Material
122001-01C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents