No.
Part name
Horizontal
1. Push the louver holder toward arrow
louver
2. Pull off the left and right chaft of
TC, TCJ sensor
1. Remove the drain pan.
2. Remove the set screws (4 positions)
3. Pull out the sensor is inserted into
Heat exchanger
1. Take down the main unit and then
2. Remove the drain pan.
3. Remove the set screws (6 positions)
Procedure
direction of right figure, and pull out
the center shaft (SM562, SM802 :
1 position, SM1102, SM1402 :
2 positions) from louver holder.
horizontal louver.
and heat exchanger support.
pipe of the heat exchanger.
treat the heat exchanger on the floor.
of fixing heat exchanger and main
unit.
Louver holder
Heat exchanger
Screws
(Fixing heat exchanger and main unit)
– 134 –
Remarks
Shaft of
horizontal louver
Screws
(Fixing heat exchanger support)
Heat exchanger support
8 -1
9 -3
10 -3