Replacing The Transducer - Titan 0558072 Operating Manual

Performance series 1150e airless high-pressure spraying unit
Table of Contents

Advertisement

Repairs at the unit
11.6

Replacing the Transducer

1. Open the relief valve, valve position PRIME (k
circulation), switch the unit OFF, and unplug the power
cord.
2. Loosen and remove the four motor shroud screws (Fig.
19, item 1). Remove the motor shroud (2).
3. At the electronic control assembly (3), disconnect the
black wire coming from the transducer (4).
4. Pull the grommet (5) out of the mounting plate (6) and
slide it up the shaft of the transducer (4) until it is clear of
the mounting plate (6).
3
6
5
4
9
5. Using a wrench, loosen and remove the transducer (4)
from the filter housing (7). Carefully thread the transducer
wire out through the mounting plate (6). Replace the
transducer cap (8) and inner seal (9), if damaged.
6. Slide the grommet (5) off of the old transducer and onto
the new transducer.
7. Thread the new transducer wire through the mounting
plate (6) and up to the electronic control assembly (3).
8. Thread the new transducer (4) into the filter housing (7)
and tighten securely with a wrench.
Make sure the transducer cap and inner seal on
i
the transducer are in place before threading the
transducer into the filter housing.
9. Push the grommet (5) into the mounting plate (6).
10. Connect the transducer wire to the electronic control
assembly (refer to the electrical schematic in Section 11.7
of this manual).
11. Slide the motor shroud (2) over the motor.
12. Secure the motor shroud (2) with the four motor shroud
screws (1).
1
2
7
8
GB
18
Performance Series 1150e

Advertisement

Table of Contents
loading

This manual is also suitable for:

0558078

Table of Contents