8.

Cleaning the unit (shutting down)

A clean state is the best method of ensuring operation without
problems. After you have finished spraying, clean the unit. Under
no circumstances may any remaining coating material dry and
harden in the unit.
The cleaning agent used for cleaning (only with an igni t ion point
above 21 °C) must be suitable for the coating material used.
• Secure the spray gun, refer to the operating manual of
the spray gun.
Clean and remove tip.
For a standard tip, refer to Page 21, Section 13.2.
If a non-standard tip is installed, proceed according to the
relevant operating manual.
1. Remove suction hose from the coating material.
2. Close the relief valve, valve position SPRAY (p spray).
3. Switch the unit ON.
4. Pull the trigger of the spray gun in order to pump the
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container.
The container must be earthed in case of coating
materials which contain solvents.
Attention
Caution! Do not pump or spray into a container
with a small opening (bunghole)!
Refer to the safety regulations.
5. Immerse suction hose with return hose into a container
with a suitable cleaning agent.
6. Turn the pressure control knob to Pulse Clean in the red
zone.
7. Open the relief valve, valve position PRIME
(k circulation).
8. Pump a suitable cleaning agent in the circuit for a few
minutes.
9. Close the relief valve, valve position SPRAY (p spray).
10. Pull the trigger of the spray gun.
11. Pump the remaining cleaning agent into an open container
until the unit is empty.
12. Switch the unit OFF.
Performance Series 1150e
GB
8.1

Cleaning unit from outside

First of all pull out mains plug from socket.
Danger of short circult through penetrating
water!
Never spray down the unit with high-pressure or
Attention
high-pressure steam cleaners.
Wipe down unit externally with a cloth which has been immersed
in a suitable cleaning agent.
8.2

Cleaning the high-pressure filter

Clean the filter cartridge regularly.
A soiled or clogged high-pressure filter can cause a poor spray
pattern or a clogged tip.
1. Turn the pressure control knob to OFF in the black zone.
unplug the power plug from the outlet.
2. Open the relief valve, valve position PRIME
(k circulation).
3. Unscrew the filter housing (Fig. 7, Item 1). with a strap
wrench.
4. Pull the filter cartridge (2) from the bearing spring (3).
5. Clean all the parts with the corresponding cleaning agent.
If necessary, replace the filter cartridge.
6. Check the O-ring (4), replace it if necessary.
7. Place the bearing ring (5) against the bearing spring (3).
Slide the filter cartridge (2) over the bearing spring.
8. Screw in filter housing (1) and tighten it as far as possible
with the strap wrench.
1
2
11
Cleaning the unit (shutting down)
5
3
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

0558078

Table of Contents