Cleaning Airless Spray Gun - Titan 0558072 Operating Manual

Performance series 1150e airless high-pressure spraying unit
Table of Contents

Advertisement

Cleaning the unit (shutting down)
8.3
Cleaning the Airless spray gun
1. Rinse Airless spray gun with an appropriate cleaning
agent.
2. Clean tip thoroughly with appropriate cleaning agent so
that no coating material residue remains.
3. Thoroughly clean the outside of the Airless spray gun.
Intake filter in Airless spray gun
1. Pull the bottom of the trigger guard forward (1) so that it
comes loose from the handle assembly (5).
2. Loosen and remove the handle assembly (5) from the gun
head (2).
3. Turning clockwise, unscrew the filter (4) from the gun body
(2).
i
Left-handed threads require turning the filter
clockwise to remove.
4. Turning counterclockwise, screw the new or cleaned filter
into the gun body.
5. Make sure all the parts are clean and the handle seal (3)
is in position inside the gun head.
6. Thread the handle assembly (5) into the gun head (2) until
secure.
7. Snap the trigger guard (1) back onto the handle assembly
(5).
1
GB
2
4
3
5
12
Performance Series 1150e

Advertisement

Table of Contents
loading

This manual is also suitable for:

0558078

Table of Contents