Gmaw Shielding Gas Hookup - Lincoln Electric LN-742 LN-742 Operator's Manual

Wire feeders
Hide thumbs Also See for LN-742 LN-742:
Table of Contents

Advertisement

A-7

GMAW SHIELDING GAS HOOKUP

WARNING
Gas under pressure is explosive.
Always keep gas cylinders in an
upright position and chained to the
undercarriage
support. See American National
Standard Z-49.1, "Safety In Welding
And Cutting", published by the
American Welding Society.
------------------------------------------------------------------------
t
t
GAS
HOSE
INERT
GAS
FITTING
INSTALLATION
Customer must provide a cylinder of shielding gas, a
pressure regulator, a flow control valve, and a hose
from the flow valve to the gas inlet fitting of the LN-742.
Install per Figure A.6 and the following:
or
a
stationary
The LN-742 can be used with any shielding gas
recommended in the electrode's product literature at a
maximum pressure of 60 psi (4.1 bar). This may
include gasses such as Argon, Helium and Nitrogen
and blended gases such as Ar-He, Ar-N 2 , Ar-O 2, Ar-
CO 2 , CO 2 , AR-CO 2 ,-O 2 .
FIGURE A.6 – SHIELDING GAS HOOKUP.
LN-742 & LN-742H
1. Connect the supply hose from the gas cylinder
flow valve outlet to the 5/8-18 female inert gas
fitting on the back panel of the LN-742.
2. Install the barbed fitting and union nut to the
5/8-18 female inert gas fitting on the front of the
LN-742. Connect 3/16 in. (4.8 mm) I.D. gas hose
from the gun to the barbed fitting.
When the gun is to be removed, this fitting can be
easily detached by loosening the union nut.
A-7
GAS
SUPPLY
HOSE