Toshiba MMK-AP0074MH-E Service Manual page 84

Hide thumbs Also See for MMK-AP0074MH-E:
Table of Contents

Advertisement

SMMS High-Wall Type
Check method
On the wired remote controller, central control remote controller and the interface P.C. board of the outdoor
unit (I/F), a check display LCD (Remote controller) or 7-segment display (on the outdoor interface P.C.
board) to display the operation is provided. Therefore the operation status can be known. Using this self-
diagnosis function, a trouble or position with error of the air conditioner can be found as shown in the table
below.
Check code list
The following list shows each check code. Find the check contents from the list according to part to be
checked.
• In case of check from indoor remote controller: See "Wired remote controller display" in the list.
• In case of check from outdoor unit: See "Outdoor unit 7-segment display" in the list.
• In case of check from AI-NET central control remote controller: See "AI-NET central control display" in
the list.
• In case of check from indoor unit with a wireless remote controller: See "Sensor block display of receiving
unit" in the list.
ALT: Flashing is alternately when there are two flashing LED.
SIM: Simultaneous flashing when there are two flashing LED.
Check code
Wired
Outdoor unit 7-
AI-NET
remote
segment display
central
controller
control
Auxiliary code
display
display
E01
E02
E03
97
E04
04
No. of indoor
units in which
E06
E06
sensor has been
04
normally
received
E07
Duplicated
E08
E08
indoor unit
96
addresses
33-EN
Installation Manual
: Lighting,
: Flashing,
: Goes off
AI-NET: Artificial Intelligence
IPDU: Intelligent Power Drive Unit
Wireless remote controller
Sensor block display of
Check code
Judging
receiving unit
name
device
Operation
Timer
Ready
Flash
Communication
error between
indoor unit and
Remote
remote controller
controller
(Detected at
remote controller
side)
Remote controller
Remote
transmission error
controller
Communication
error between
indoor unit and
Indoor unit
remote controller
(Detected at
indoor unit side)
Communication
circuit error
between indoor /
Indoor unit
outdoor unit
(Detected at
indoor unit side)
Decrease of No. of
indoor units
Communication
circuit error
between indoor /
outdoor unit
(Detected at
outdoor unit side)
Duplicated indoor
Indoor unit •
unit addresses
– 33 –
SMMS High-Wall Type
Wired
remote
controller
display
E09
E10
E12
E15
E16
E18
E19
E20
E21
E22
E23
I/F
E25
I/F
E26
E28
I/F
Check code
Wireless remote controller
Outdoor unit 7-
AI-NET
Sensor block display of
segment display
central
receiving unit
control
Auxiliary code
Operation
Timer
Ready
display
99
CF
01:Indoor /
Outdoor units
communication
E12
42
02:Outdoor /
Outdoor units
communication
E15
42
00:Capacity
over
E16
89
01 ~:No. of
connected units
97, 99
00:No header
E19
02:Two or more
96
header units
01:Outdoor unit
of other line
connected
E20
42
02:Indoor unit of
other line
connected
02:No header
unit
E21
00:Multiple
42
number of
header units
E22
42
E23
15
E25
15
No. of outdoor
units which
E26
15
received signal
normally
Detected
E28
outdoor unit
d2
number
– 34 –
Installation Manual
Check code
Judging
name
device
Flash
Duplicated master
Remote
remote controllers
controller
Communication
error between
Indoor unit
indoor unit MC
Automatic address
I/F
start error
No indoor unit
during automatic
I/F
addressing
Capacity over /
No. of connected
I/F
indoor units
Communication
error between
header and
Indoor unit
follower units
Indoor unit
Outdoor header
I/F
units quantity error
Other line
connected during
I/F
automatic address
Error in number of
heat storage
I/F
master units
Reduction in
number of heat
I/F
storage units
Sending error in
communication
between outdoor
units
I/F
Error in number of
heat storage units
(trouble with
reception)
Duplicated
follower outdoor
I/F
addresses
Decrease of No. of
connected outdoor
I/F
units
Follower outdoor
I/F
unit error
34-EN