DSR-PD170/PD170P/PD190P
13. White Balance ND Filter 1 Compensation
Compensate the white balance deviation when ND FILTER switch
is "1".
Subject
Adjustment Page
Adjustment Address
Note1: After the power is turned on, this adjustment can be done only
once.
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
ND FILTER ........................................................................... 1
(The data of page: 6, address: 9D is "01".)
Adjusting method:
Order Page Address Data
1
0
01
2
6
01
3
6
01
4
6
02
Note3: The adjustment data will be automatically input to page: F, address:
4A and 4B.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
6
02
3
0
01
Clear chart
(Color bar standard picture frame)
F
4A, 4B
Procedure
01
Set the data.
11
Set the data, and press PAUSE
button.
09
Set the data, and press PAUSE
button. (Note3)
Check that the data changes to
"01".
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
14. White Balance ND Filter 2 Compensation
Compensate the white balance deviation when ND FILTER switch
is "2".
Subject
Adjustment Page
Adjustment Address
Note1: After the power is turned on, this adjustment can be done only
once.
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
ND FILTER ........................................................................... 2
(The data of page: 6, address: 9D is "02".)
Adjusting method:
Order Page Address Data
1
0
01
2
6
01
3
6
01
4
6
02
Note3: The adjustment data will be automatically input to page: E, address:
8E and 8F.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
6
02
3
0
01
4
6-24
Clear chart
(Color bar standard picture frame)
E
8E, 8F
Procedure
01
Set the data.
CF
Set the data, and press PAUSE
button.
CD
Set the data, and press PAUSE
button. (Note3)
Check that the data changes to
"01".
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
Set ND FILTER switch to
"OFF".