Changing The Floor-Tool Blades - Numatic TTB 4055 Owner's Instructions Manual

Scrubber dryer
Hide thumbs Also See for TTB 4055:
Table of Contents

Advertisement

!
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED PRIOR TO ANY
The floor-tool
The TTB range is provided with the aluminium floor-tool shown.
To clean the floor-tool, remove securing-pin and pull-free from the holder, disconnect the lifting strap
(see Page 11).
Rinse the floor-tool assembly with clean water and refit.
Periodically the floor-tool blades should be examined and checked for wear and damage.
The blade removal is easy. Simply start by removing the four retaining pins (see Fig.46), turn the
floor-tool over and separate the blade carrier from the body (see Fig.47).Peel away the blades from their locating
lugs (see Fig.48) and examine or renew as required.
Replacement is a reversal of the removal process.
Floor-tool overview
1. Floor-tool main body
2. Rear blade
3. Blade carrier
4. Front blade (slotted)
5. Retaining pins x 4
Note:
The blades are designed to be reversible, thus extending their useful working life.
Changing the Floor Tool Blades
MAINTENANCE
Fig.47
1
2
3
4
16
Fig.46
Fig.48
5
!

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ttb 100t