Baxi Maxflow Combi WM Installation And Servicing Instructions page 36

Gas fired wall mounted combination boiler with unvented hot water storage
Table of Contents

Advertisement

Pump Wiring Cover
Socket Head
Fig. 83
Pump Setting
Pump Wiring Cover
36
Fig. 81
Pump Body
Screw
Pump Head
11.20
1. Drain the primary circuit and remove the
socket head screws securing the pump head to
the body and draw the head away.
2. Undo the screw on the pump wiring cover and
remove the cover. Using a suitable flat bladed
screwdriver press the cable securing levers
downwards to release each wire after noting their
position.
3. A standard Grundfos 15-60 replacement head
can now be fitted. Connect the wiring to the new
head. The pump speed must be set to 3.
4. Reassemble in reverse order.
11.21
1. Drain the primary circuit and unscrew the
automatic air vent from the pump body. Undo the
union nuts on the inlet and outlet connections and
draw the pump forwards.
2. Undo the screw on the pump wiring cover and
remove the cover. Using a suitable flat bladed
screwdriver press the cable securing levers
downwards to release each wire after noting their
position.
3. Connect the wiring to the new head and set
Fig. 82
the pump speed to 3. Using new sealing
washers fit the new pump, fit the air vent to the
pump body and reassemble in reverse order.
11.22
1. Drain the primary circuit and unscrew the the
automatic air vent from the pump body.
Automatic Air Vent
2. Examine the "O" ring seal, replacing if
necessary, and fit it to the new automatic air vent.
3. Reassemble in reverse order, repressurising
the system if necessary.
Fig. 84
11.0 Changing Components
Pump - Head Only (Figs. 82 & 83).
Pump - Complete (Figs. 83 & 84).
Automatic Air Vent (Fig. 84)