Baxi Maxflow Combi WM Installation And Servicing Instructions page 35

Gas fired wall mounted combination boiler with unvented hot water storage
Table of Contents

Advertisement

Expansion
Vessel
Fig. 77
Mounting
Bracket
Expansion Pipe
Storage Tank
Temperature &
Pressure Relief Valve
Discharge Pipe
Fig. 79
Retaining Clip
Discharge Pipe
11.0 Changing Components
11.18
Expansion Vessel (Fig. 77)
1. Drain the primary circuit and undo the nut on
the expansion pipe at the adaptor on the bottom
of the vessel.
2. Undo the nut and washer securing the vessel to
the mounting bracket on the side of the storage
tank.
3. Lift the vessel slightly to disengage the adaptor
from the mounting bracket. Remove the vessel
from the appliance.
4. Reassemble in reverse order.
11.19
Storage Tank Temperature &
Pressure Relief Valve (Fig. 79)
1. It is necessary to remove the expansion vessel
Fig. 78
as described in 11.18 prior to changing the relief
valve.
2. Undo the nut on the discharge pipe at the valve
and ease the pipe out of its retaining clip on the
case side.
3. Undo the nut on the temperature and pressure
relief valve securing it to the spigot on the storage
tank and remove the valve.
4. Ensure that the sealing washer is in place and
fit the new valve. Reassemble in reverse order.
Fig. 80
35