Baxi Maxflow Combi WM Installation And Servicing Instructions page 16

Gas fired wall mounted combination boiler with unvented hot water storage
Table of Contents

Advertisement

Fig. 18
Adhesive Seal
16
Fig. 17
Flue Trim
Fig. 20
7.0 Site Requirements
7.9
Flue Dimensions
The standard horizontal flue kit allows for flue
lengths between 100mm and 1m from elbow to
terminal (Fig. 17).
The maximum permissible equivalent flue
length is: 4 metres.
NOTE: Each additional 45° of flue bend will
account for an equivalent flue length of 0.5m.
eg. 45° = 0.5m,
7.10
Flue Terminal Trim
1. Once the flue is secure the trim can be fitted if
required.
2. Remove the protective backing from the
adhesive seal. Apply the seal to the rear of the
trim flange (Fig. 18).
3. Locate the trim over the flue terminal and push
it back to the wall to compress the seal (Fig. 19).
Fig. 19
7.11
Terminal Guard (Fig. 20)
1. When codes of practice dictate the use of
terminal guards, they can be obtained from most
Plumbers' and Builders' Merchants.
2. There must be a clearance of at least 50mm
between any part of the terminal and the guard.
3. When ordering a terminal guard, quote the
appliance name and model number.
4. The flue terminal guard should be positioned
centrally over the terminal and fixed as illustrated.
90° = 2 x 45° = 1m etc.