Gas fired wall mounted combination boiler with unvented hot water storage
Table of Contents

Advertisement

10
6.0 System Details
6.3
Bypass
1. The boiler has an integral bypass and in most
cases this should suffice. However in certain
circumstances, e.g. on systems where there is a
high resistance and TRV's are fitted to all the
radiators it may be necessary to fit an external
by-pass. For example, a 15mm pipe between the
flow and return controlled by a valve, or an
uncontrolled radiator.
6.4
System Control
1. The boiler is designed for use in a heating
system that incorporates external controls, i.e. a
minimum of a timer device.
2. Suitable timer kits are available as optional
extras.
3. For optimum operating conditions and
maximum economy the fitting of a programmable
thermostat, such as the Baxi Maxflow Combi WM
Controller, is recommended.