Cleaning The Casing Material; Precautions Required In The Case Of Long Boiler Stops (One Or More Years); Precautions Required If The Heating Is Stopped When There Is A Risk Of Freezing - REMEHA P 320-4 Technical Instructions

Fuel oil/gas boilers
Table of Contents

Advertisement

Positioning of the baffles
The first two baffles on the two lower flue ways are fitted
with stops to position them in the right place.
(1) Stop
Baffle plates
410 mm
upper
570 mm
interior
412 mm
Maintenance of the burner
Refer to the instructions supplied with the burner

2 Cleaning the casing material

Use a soapy solution and a sponge only. Rinse with clean water and
dry with chamois leather or a soft cloth.

3 Precautions required in the case of long boiler stops (one or more years)

- The boiler and the chimney must be swept carefully.
- Close all the doors of the boiler to prevent air from circulating inside
the boiler.

4 Precautions required if the heating is stopped when there is a risk of freezing

We recommend the use of a correctly dosed antifreeze agent to
prevent to the heating circuit from freezing. If this cannot be done,
drain the system completely.
06/04/06 - 300008452-001-C
Flue ways
P 320-4
P 320-5
A + B
-
A + B
4
C
2
Remeha P 320
Cleaning the flue gas box
- Remove the left and right cleaning hatches from the flue gas box
(2 butterfly nuts) and use a vacuum cleaner to remove any soot
which has accumulated
- Replace the cleaning hatches.
P 320-6
P 320-7
8
8
-
-
-
4
2
2
2
- We advise removing the pipe which connects the boiler to the
chimney and to close off the nozzle with a cover.
P 320-8
P 320-9
-
-
4
4
2
2
15