Titan SPEEFLO Commander 741-440 Owner's Manual page 36

Air powered airless sprayer
Table of Contents

Advertisement

commander™ Outlet accessories
1 2 3
4
Service Instructions
The 944-620 Series Bleed Valve has a tungsten carbide seat
(9) and should not require frequent replacement. The tungsten
carbide ball (7), in normal service, will last a long time because it
rotates and wears evenly. If there is leakage, replace the ball.
IMPORTaNT: Open the adjustment knob (1) to full
counterclockwise position before unthreading valve seat (9)
from valve body (4).
If the valve stem (3) is rotated inwardly with the ball removed,
the Teflon O-ring (5) may require replacement. If there has
been leakage from the valve stem, the Teflon O-ring should be
replaced.
IMPORTaNT: The valve stem stop (6) must be unthreaded
from the valve stem (3) with a socket screwdriver, then the
valve stem can be threaded out of the valve body.
IMPORTaNT: all non-moving threads must be assembled
with Loctite sealant, Titan part # 426-051.
944-050 Bleed valve Service Kit
ITEM
PaRT
DEScRIPTION
NO.
NO.
5
944-005
O-ring
7
569-170
Ball, T.C.
8
945-003
Gasket, copper
5
6
7
8
9
ITEM
PaRT
NO.
NO.
1
944-005
2
860-721
3
944-023
4
944-020
5
944-004
6
944-026
7
569-170
8
945-003
9
944-904
QTy.
1
1
1
36
944-620 Bleed valve assembly
DEScRIPTION
Knob
Nut, lock
Valve stem
Valve body
O-ring
Valve stem stop
Ball, T.C.
Gasket, copper
Valve seat
© Titan Tool Inc. All rights reserved.
QTy.
1
1
1
1
1
1
1
1
1