Motorola DCH200 Installation Manual page 44

Hide thumbs Also See for DCH200:
Table of Contents

Advertisement

4 DIAGNOSTICS
Field
MAC Abort
Cntr
Socket Port
State
Description
WAIT_SO_ACK
WAIT_LA_OR_SO
INIT_STOPPED
RUN_WAIT_DC_OR_C
RUNNING
RUN_STOPPED
INVALID
This counter increments every time the MAC layer reaches the cell abort count limit. It is
reset by the successful upstream transmission of a cell, for example, when an ACK is
received by the set-top. If the counter reaches the MAC abort count limit, the DCH200
assumes the MAC layer is unavailable due to noise, congestion, or some other problem.
The DCH200 stops transmitting data upstream, reports an error to the calling function,
and attempts to re-enter the network using the initialization process. 0000 is displayed as
default or if the MAC Abort CNTR is not configured or unknown.
The socket mode and activity:
UNUSED — The socket is not being used.
OPENED — The socket is open.
READY — The socket is ready to send or receive.
RECVING — The socket is receiving data from the application server.
SENDING — The socket is sending data to the application server.
The set-top is in the interactive initialization state and
waiting for a Sign On acknowledgement.
The set-top is in the interactive initialization state and
waiting for Logical Address or Sign On with verification
Frequency message.
The set-top is in the interactive initialization state and the
TransMode has stopped.
The set-top is in the interactive state and waiting for the
default configuration or the contention channel list
messages.
Interactive state is running, sending idle messages, and
waiting for any prepare for poll or MAC messages.
The interactive run state has stopped and the set-top is
waiting for status or transmission control message.
The interactive state is unknown or invalid.
36

Advertisement

Table of Contents
loading