Check the appliance is electrically safe and gas sound when you have finished.
Fig.7-3
Gas inlet block
800
600
All dimensions in millimetres
Fig.7-4
Live: brown
L
Earth: yellow & green
Fig.7-5
Earth: to the
terminal marked E,
coloured Green/Yellow
Neutral: to the
terminal marked N,
coloured Blue
400
A
300
Neutral: blue
N
Live: to the
terminal marked L,
coloured Brown
INSTALLATION

Gas Connection

This must be in accordance with the relevant standards.
The flexible hose (not supplied with the cooker) must be
in accordance with the relevant standards. Hoses may be
purchased at most builders' merchants.
The gas supply needs to terminate with a down-facing
bayonet.
The connector is located just below the hotplate level at the
rear of the cooker. If in doubt contact your supplier.
Because the height of the cooker can be adjusted and each
connection is different, it is difficult to give precise dimensions.
The maximum length of the hose should not exceed 1500mm
The hose should be fitted so that both inlet and outlet
connections are vertical so that the hose hangs downwards in
a 'U' shape.
Ideally the hose supply connection should be within the
shaded area 'A' (Fig.7-3).
For Natural Gas, the flexible hose must be in accordance with
BS 669. For LP Gas, it should be capable of 50 mbar pressure
and 90 °C temperature rise. If in doubt contact, your supplier.
After completing the gas connection, make sure that the
cooker is gas sound with soapy water or leakage fluids.

Electrical Connection

All external wiring must comply with the IEE Regulations
for the Electrical Equipment of Buildings. Connection to the
electrical supply is via a plug and socket.
Do not use an extension lead.
WARNING: THIS APPLIANCE MUST BE EARTHED.
n
n
Three pin plugs to BS 1363 with a capacity of not less than
13 A must be used and fitted with a 13 amp fuse 'ASTA'
approved to BS 1362.
You MUST refit the cover after replacing the fuse. If the cover
is lost, the plug MUST NOT be used until a replacement cover
has been obtained from your supplier. The colour of the
correct fuse carrier is that of the coloured insert in the base of
the fuse recess, or stated elsewhere on the plug. Always state
this colour when ordering a replacement fuse carrier.
IMPORTANT: The wires in the mains lead are coloured in
accordance with the following code
Green and yellow:
Blue:
Brown:
16
(
and
Fig.7-4
Fig.7-5
EARTH
NEUTRAL
LIVE
)
: