Inspections (In Normal Mode); 1Electrical Performance; Withstand Voltage; Grounding Conductivity Check - NEC FP1355 Service Manual

High resolution display monitor
Hide thumbs Also See for FP1355:
Table of Contents

Advertisement

2.5

Inspections (In normal mode)

Status
Inspections
indicator
2.5.1
Electrical performance
Inspect the electrical performance by setting contrast to MAX and bright to center (press (-) (+)
buttons simultaneously).
2.5.1.1

Withstand voltage

There must be no abnormality when 1500VAC is applied for two seconds between both ends of
the AC input terminal and chassis, and between the DG coil terminal and chassis.
2.5.1.2

Grounding conductivity check

Check that the resistance value is 100m ¶ or less when 25A is pa ssed between the AC input
terminal grounding GND and chassis GND.
2.5.1.3

Degaussing coil operation

Confirm that when OSD DEGAUSS is executed, the picture vibrates and then stops.
2.5.1.4
IPM (POWER SAVE) function operation (Set the AC power input to 230V)
Use the full white pattern without R, G, B signals.
Select IPM from the OSD, and set the POWER-SAVE function ON.
(1) IPM (POWER SAVE) ON
(a)Confirm that when H and V SYNCs are removed, and then the picture darkens.
After 8 seconds, also confirm that the power LED changes to orange and the power
consumption is as follows.
(b)Confirm that when SYNC is input again, the high voltage is recovered, and the picture
appears in approx. five seconds.
Adjustment item
Normal mode
Confirmation timing
Timing No. 12 (106.25kHz / 85Hz, 1600x1200)
Power consumption
Adjustment mode/set
3W or less
2 - 24