Figure 10. Alarm Closure Connector; Figure 11. Alarm Closure Switch Cable - PESA Tiger Owner's Manual

Audio routing switcher
Hide thumbs Also See for Tiger:
Table of Contents

Advertisement

$ODUP &RQQHFWRUV
$ODUP 6ZLWFK &RQQHFWRU $/$50 &/2685(
This 3-contact connector provides an optically isolated switch closure during an alarm condition. For
more information on alarm conditions, see "Alarm Signal Monitoring" on page 43. See Figure 10 for
an orientation view showing contact locations.
ALARM CLOSURE is connected to an external, customer supplied, monitoring circuit with a cable
constructed with one 3-contact, screw-terminal connector (PESA Part No. 81-9029-0811-0) and
customer supplied cable, as shown in Figure 11. The connector body has an integral strain relief which
requires the use of a nylon cable tie (PESA Part No. 81-9021-0028-8).

7LJHU $XGLR 5RXWLQJ 6ZLWFKHU

Figure 10. ALARM CLOSURE Connector

Figure 11. Alarm Closure Switch Cable

&$87,21
The alarm circuit connected to this connector must not exceed
12VDC or 10mA.
&KDSWHU  ± ,QVWDOODWLRQ