19.1. Errors, meaning, causes and suggested solutions
Error display
Meaning
Mains Fail
230V AC system power
supply missing.
WAM__ PSU Fail
230V AC power supply
missing in universal module.
Batt low
No battery power supply to
system.
WAM__ Low Batt
No battery power supply to
universal module.
Possible causes
The main fuse of the transformer of the
•
radio alarm system is not fitted correctly or
defective.
The connecting cable between the
•
system and the base plate is not inserted
correctly.
The main power supply to the transformer
•
of the base plate has failed or the power
cable was not fitted correctly.
Defect of base plate transformer.
•
The mains power cable to the 12V supply
•
is not correctly connected.
The transformer is not supplied with power.
•
The transformer that supplies power to the
•
universal module is defective.
The system batteries are not fully charged.
•
The lead-acid battery is not yet charged.
•
No lead-acid battery was connected.
•
35
Suggested solutions
Replace the main fuse.
•
Check the fuse is correctly fitted.
•
Check for correct installation of the system
•
with the base plate and plug the
connecting cable into the proper base
plate socket.
Check that your mains power fuse is
•
active for the system. Is there a 230V
power supply?
Check for correct connection between
•
the mains power line and the transformer
clamp.
Contact your installer.
•
Check for correct installation of the 12V
•
DC connecting cable.
Check that the transformer is plugged in
•
and the red LED on the transformer is
alight.
Contact your installer.
•
This error should disappear when the
•
batteries are fully charged.
After max. 4 hours, the batteries are
•
charged and this display disappears.
This error should disappear when the
•
battery is fully charged.
Check for correct installation of the 6V,
•