13. In case of alarm
The radio alarm system has three different alarm types. Depending on the system state (deactivated, internally activated, activated) or triggered
alarm zone (technical alarm, panic alarm, intrusion alarm, fire alarm ...), one of the following alarms can be triggered:
Local/Internal Alarm
•
External alarm
•
Silent alarm
•
13.1. Local/Internal alarm
In the case of a local alarm, the following
are activated:
The alarm system siren
•
The info module siren
•
Only local alarm: The external siren
•
(where the acoustic alarm is active
for 3 minutes, and the visual alarm is
active until the system is
deactivated)
The relay of the universal modules if
•
programmed
.
A local alarm is caused by:
A tamper alarm in deactivated
•
system state
An alarm in the technical zones
•
An alarm in each zone of the system
•
(except zones with entry/exit delay)
An unsuccessful activation die to
•
exceeding the exit delay time
Exceeding the first entry delay time
•
Whatever type of alarm is triggered, keep calm. Not every alarm is an intrusion. Most alarms have other causes. Check the situation carefully and take
considered action accordingly. Deactivate the system, check the reason for the alarm and then reset the alarm. If you receive news of the alarm by
telephone, follow the steps in section 15.
13.2. External alarm
In the case of an external alarm, the
following are activated:
The alarm system siren
•
The info module siren
•
The external siren (where the acoustic
•
alarm is active for 3 minutes, and the
visual alarm is active until the system
is deactivated)
Alarm transmission by telephone
•
The relay of the universal modules if
•
programmed
.
An external alarm is caused by:
A tamper alarm in activated system
•
state
An alarm of the 24-hour zones and
•
the fire zones in active and inactive
system state
An alarm in each zone of the system
•
(except zones with entry/exit delay)
Exceeding the second entry delay
•
time
15
13.3. Silent alarm
In the case of a silent alarm, the following
are activated:
No acoustic or visual alarm
•
Alarm transmission by telephone only
•
The relay of the universal modules if
•
programmed
.
A silent alarm is caused by:
A panic alarm if programmed
•
An alarm in each zone of the system
•
(except zones with entry/exit delay)
in active system state if programmed