Please Note: It is important that you read instructions before installing or operating gas logs
Gas logs are to be burned only in approved woodburning Fireplace with adequate chimney draft. When burning, the chimney
damper must be FULLY OPEN. Log set must be installed in fireplace which operates properly when wood fires are burned.
• For best results, natural gas pressure must be 7" to 10-1/2" water
column.
• To simulate real wood burning, the gas burner is designed to burn a
yellow flame. It is normal for the logs to soot-up. The soot can easily be
removed with a vacuum cleaner or a soft brush.
• A fireplace screen must be in place when the appliance is operating
and, unless other provisions for combustion air are provided, the screen
shall have an opening (s) for introduction of combustion air.
• If used with glass fireplace doors, burn with doors in open position.
• Do not burn wood or other items with log set.
Log sets are designed for use with Natural Gas, unless clearly labeled for Propane (LP). Never use Propane Gas in a log set
designed for Natural Gas, or Natural Gas in a log set designed for use with Propane Gas.
The installation, including provisions for combustion and ventila-
tion air, must conform with local codes or, in the absence of local
codes, with the national fuel Gas Code, ANSI Z223.1-1988 and
NFPA54-1988.
The appliance and its individual shutoff valve must be disconnect-
ed from the gas supply piping system when testing at test pressures
in excess of 1/2 psig.
The appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of gas-supply system at test pressures equal to
or less than 1/2 psig. This is accomplished by closing the gas sup-
ply line valve, which is required by NFPA 54, section 5.54.
"BIG TEX" VENTED GAS LOGS

GENERAL INFORMATION

IMPORTANT INFORMATION
CHECK TO BE SURE LOG SET IS FOR PROPER GAS TYPE
FOR YOUR SAFETY
If you smell gas:
1. Open Windows.
2. Don't Touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
The minimum inlet gas supply pressure for the purpose
of input adjustment is 7" WC for Natural Gas and 11"
WC for Propane Gas.
The maximum inlet gas supply pressure for this burner
is 10.5" for Natural Gas and 13" for Propane Gas.
IMPORTANT: MINIMUM SPECIFICATIONS
LISTED IN THE CHART ON PAGE 2 OF THESE
INSTRUCTIONS MUST BE MET TO SAFELY
INSTALL AND OPERATE THIS GAS LOG SET.

Advertisement

loading

Summary of Contents for Golden Blount BIG TEX BT24

  • Page 1: Installation And Operating Instructions

    INSTALLER! PLEASE LEAVE WITH HOMEOWNER INSTALLATION AND OPERATING INSTRUCTIONS “BIG TEX” VENTED GAS LOGS Please Note: It is important that you read instructions before installing or operating gas logs GENERAL INFORMATION Gas logs are to be burned only in approved woodburning Fireplace with adequate chimney draft. When burning, the chimney damper must be FULLY OPEN.
  • Page 2: Components Parts

    “BIG TEX” SPECIFICATIONS MODEL # MINIMUM MINIMUM SEE-THRU OVERALL MINIMUM MINIMUM REQUIRED REQUIRED MINIMUM HEIGHT REQUIRED REQUIRED WIDTH DEPTH DEPTH WITH LOGS BTU GAS PIPING BT24 34" 20" 24" 18" 80,000 1/2" I.D. BT30 40" 20" 28" 18" 90,000 1/2" I.D. BT36 46" 22" 28" 20"...
  • Page 3: Before Lighting

    To Install Gas Log Set: 1. Attach damper clamp to fireplace damper to prevent damper from being fully closed. 2. Position burner assembly into fireplace and position in center and as far toward the rear as possible (See “Big Tex” Specifications for allowable dimensions). Figure 3-1 Figure 3-2 3. Attach aluminum connector to gas supply line and connect to burner assembly. Use soapy water to check connections for leaks. 4. Pour silica sand into raised rear burner completely covering pipe in pan. For LP Gas models, use vermiculite instead of sand. (Figure 3-1) 5. Place glowing ember material over sand (vermiculite LP). (Figure 3-2) 6. Pour vermiculite over lower adjustable burner. (Figure 3-3) Figure 3-3 Figure 3-4 7. Place glowing ember material over vermiculite and upward covering sheet metal deflector. (Figure 3-4) 8. Spread the black volcanic cinders in front...
  • Page 4: For Your Safety Read Before Lighting

    2. To shut OFF the main burner and pilot, turn the gas control knob clockwise to the OFF position. This action will close the main gas valve and disengages the safety pilot valve. However, the power unit must drop out before the light- ing sequence can begin again. This may take as long as 3 minutes. 3. To relight the pilot, follow the steps in the Pilot Gas and Lighting Procedure section. ALL GOLDEN BLOuNT GAS LOG PRODuCTS uSING ThE 3 IN 1 GAS CONTROL VALVE CAN BE EASILY CONVERTED TO AN OFF/ON SOLENOID OR AN ADJuSTABLE MOTOR FLAME hEIGhT. ASK YOuR DEALER OR CALL 1-800-833-1139.
  • Page 5: For Your Safety

    HIGH OUTPUT GAS CONROL VALVE LIGHTING INSTRUCTIONS Pilot burner location Nat. Gas models Gas Control Knob FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, Pilot burner location personal injury or loss of life.
  • Page 6: Limited Warranty

    LIMITED WARRANTY Golden Blount Gas Logs are warranted against defective materials and/or workmanship for as long as you own them. Burner pan assemblies are guaranteed for five years from date of purchase. Safety Pilot Assemblies are covered for one year. This warranty does not cover parts subjected to misuse, abuse, improper handling or improper installation. The GB warranty specifically excludes any liability for indirect, incidental or conse- quential damage to property. Defective logs or defective parts should be returned to your dealer or to the factory prepaid with a copy of your sales receipt. Defective parts will be repaired or replaced at the factory’s option and returned to you prepaid. GOLDEN BLOUNT – 4301 WESTGROVE DRIVE – ADDISON, TX 75001...

This manual is also suitable for:

Big tex bt30Big tex bt36Big tex bt42Big tex bt48Big tex bt60Big tex bt72