Download Print this page

For Your Safety Read Before Lighting; Shut Off Procedure - Golden Blount BIG TEX BT24 Installation And Operating Instructions Manual

Vented gas logs

Advertisement

FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
1. This product has a standing pilot, which must be lit by hand. When lighting the pilot, follow these instructions exactly.
2. This installation should be installed including provisions for combustion and ventilation air, must conform with local
codes or, in the absence of local codes, to the National Fuel Gas Code, ANSI Z223 latest edition.
3. This product must be on a gas supply line that is less than 1/2 psi. and with an individual manual shut off.
4. Never operate this new system with the glass fireplace enclosures (doors) in the closed position.
5. Connecting 110-volt electrical power to this product will cause damage and will void warranty.
3 IN 1 GAS CONROL VALVE LIGHTING INSTRUCTIONS
Pilot Gas and Lighting Procedure
DAMPER MuST BE FuLLY OPENED
1. Turn the gas control knob counter-clockwise to the
PILOT position, push the gas control valve IN and HOLD
in position. This will open the pilot valve and allow gas to
flow to the pilot burner.
2. Light the pilot burner while holding the gas control knob
in until a strong pilot flame is present (approximately 60
seconds).
3. Release the gas control knob. The gas control knob will hold in and engages the valve power unit.
4. Turn the gas control knob counter-clockwise to the ON position. The main burner valve will open and the main
burner will ignite.

Shut Off Procedure

1. To shut OFF the main burner but leaving the pilot ON, turn the gas control knob clockwise to the PILOT position.
This action will close the main gas flow.
2. To shut OFF the main burner and pilot, turn the gas control knob clockwise to the OFF position. This action will
close the main gas valve and disengages the safety pilot valve. However, the power unit must drop out before the light-
ing sequence can begin again. This may take as long as 3 minutes.
3. To relight the pilot, follow the steps in the Pilot Gas and Lighting Procedure section.
ALL GOLDEN BLOuNT GAS LOG PRODuCTS uSING ThE 3 IN 1 GAS CONTROL VALVE CAN BE EASILY CONVERTED TO AN
OFF/ON SOLENOID OR AN ADJuSTABLE MOTOR FLAME hEIGhT. ASK YOuR DEALER OR CALL 1-800-833-1139.
Pilot Adjustment
Gas Control Knob
Removable Plug
for ON/OFF Solenoid
or hI/LO Adjustable
Motor Installation
4
Pilot burner location
Nat. Gas models
Pilot burner location
LP Gas models

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Big tex bt30Big tex bt36Big tex bt42Big tex bt48Big tex bt60Big tex bt72