Handling Of Service Tools; Manifold Gauge Set - Kubota M105S Workshop Manual

Hide thumbs Also See for M105S:
Table of Contents

Advertisement

M105S, WSM
(Reference)
Replacing Parts
Condenser
Evaporator
Receiver
*PAG : Polyalkyleneglycol (Synthetic oil)

[1] HANDLING OF SERVICE TOOLS

(1) Manifold Gauge Set

Replenish Quantity
20 cc
0.021 U.S.qts
0.018 Imp.qts
20 cc
0.021 U.S.qts
0.018 Imp.qts
10 cc
0.011 U.S.qts
0.009 Imp.qts
The hand valves on the manifold gauge set are used to open and
close the valve. The hand valve inscribed LO is for the low pressure
side valve (3) and HI is for the high pressure side valve (4). By
opening or closing the high and low pressure hand valves, the
following circuits are established.
(1) LO Pressure Gauge
(2) HI Pressure Gauge
(3) LO Pressure Side Valve
When LO Pressure Side Valve and HI Pressure Side Valve
are Closed
Two circuits are established.
Port (C) → LO pressure gauge (1)
Port (A) → HI pressure gauge (2)
NOTE
• Schrader valve (D) must be opened.
When LO Valve is Opened and HI Valve is Closed
Two circuits are established.
Port (C) → LO pressure gauge (1)
Port (A) → HI pressure gauge (2)
NOTE
• Schrader valve (D) must be opened.
Brand Name
ND-ACEITE 8<PÁG* oil>
→ Port (B)
→ Port (D)
10-S10
W1012709
(4) HI Pressure Side Valve
(5) Schrader Valve
W1013107
W1013376
W1013454
KiSC issued 03, 2007 A
CABIN

Advertisement

Table of Contents
loading

Table of Contents