(10) Auxiliary Control Valve Wire
Adjusting Wire of Auxiliary Control Valve
1. (Valve side) : Set the lock nut (2) at center of wire's threads.
2. (Lever side) : Screw in the wire (3) to the rod end (4) until 5 mm
(0.2 in.) of wire's threads remaining.
3. Shift the control lever (7) forward, and check the clearance
between the stopper and lever.
4. If the clearance is out of specified value, adjust by the nut (6).
Clearance between
Factory spec.
stopper and lever
(1) Auxiliary Control Valve
(2) Lock Nut
(3) Wire
(4) Rod End
8-S23
HYDRAULIC SYSTEM
0 to 1.0 mm
0 to 0.039 in.
(5) Threads
(6) Lock Nut
(7) Control Lever
W1031644
KiSC issued 03, 2007 A