(2) Main Switch

Battery Storage
1. When shutting down the tractor for long periods of time, remove
the battery from the tractor, store the battery in a well ventilated
placed where it is not exposed to direct sunlight.
2. Since the battery self-discharges by approx. 0.5 % per day even
in storage, it must be once every two months in cold season.
3. When storaging the battery mounted on the tractor, disconnect
the ground cable from the battery's negative terminal post.
(Reference)
• Self-discharge Rate
Temperature
30 °C (86 °F)
20 °C (68 °F)
10 °C (50 °F)
Preparation
1. Remove the meter panel, and disconnect the hourmeter cable
and the main switch connectors after turning the main switch off.
2. Perform the following checking.
(1) Main Switch
Connector Voltage
1. Measure the voltage with a voltmeter across the connector 3
terminal and chassis.
2. If the voltage differs from the battery voltage (11 to 14 V), the
wiring harness is faulty.
Connector 3 terminal -
Voltage
Chassis
(1) Main Switch (Switch Side)
9-S11
ELECTRICAL SYSTEM
Self-discharge rate
Approx. 1.0 % per day
Approx. 0.5 % per day
Approx. 0.25 % per day
W1017453
W1017794
Approx. battery voltage
(2) Main Switch Connector
(Wire Harness Side)
W1018057