Piranha HS-xx RoHS User Manual
Verify Voltage
Use the
Verify Temperature
To check the internal tem peratu re of the cam era, u se the
operation, this valu e shou ld not exceed 75°C.
Note:
If this occu rs, the cam era must be rebooted u sing the com m and ,
d ow n m anu ally. You w ill have to correct the tem peratu re problem or the cam era w ill
shu td ow n again. If you enter any com m and other than
w ith:
Error 09: The camera's temperature exceeds the specified operating
range>
Verify Pixel Coefficients
Use the
PRN U... The cam era also retu rns the pixel nu m ber for each fifth pixel.
End-of-line Sequence
To fu rther aid d ebu gging, the cam era can generate an end -of-line sequ ence. The end -of-
line-sequ ence ou tpu ts "aa", "55", "line cou nter", "line average", "pixels above threshold ",
"pixels below threshold ". To activate the end -of-line sequ ence, u se the com m and
To d isable the end -of-line sequ ence, u se the com m and
Use the
m od es, or 0 to 4096 for 12 bit d ata m od es.

Specific Solutions

No Output or Erratic Behavior
If you r cam era provid es no ou tpu t or behaves erratically, it m ay be picking u p rand om
noise from long cables acting as antennae. Do not attach w ires to u nu sed pins. Verify that
the cam era is not receiving spu riou s inpu ts (e.g. EXSYN C if cam era is in exposu re m od e
that requ ires external signals). Unu sed signals in the Cam era Link cable shou ld be
term intated in 100Ω.
Teledyne DALSA
the analog offset u sing the
shou ld receive a valu e.
vv com m and to d isplay the cam era's inpu t voltage.
If the cam era reaches 75°C, the cam era w ill shutdow n and the LED w ill flash red.
dpc com m and to d isplay the pixel coefficients in the ord er FPN , PRN U, FPN ,
sut and slt com m and s to set threshold valu es betw een 0 and 255 for 8 bit d ata
cao or sao com m and s. Und er light cond itions, you
vt
els 0 .
vt com m and . For proper
rc
or can be pow ered
rc
or
, the cam era respond s
els 1 .
03-032-20013-04