Sign In
Upload
Manuals
Brands
Teledyne Manuals
Amplifier
H-SERIES
User Manuals: Teledyne H-SERIES Outdoor Power Amplifier
Manuals and User Guides for Teledyne H-SERIES Outdoor Power Amplifier. We have
1
Teledyne H-SERIES Outdoor Power Amplifier manual available for free PDF download: Operation Manual
Teledyne H-SERIES Operation Manual (134 pages)
High Power Outdoor Solid State Power Amplifier
Brand:
Teledyne
| Category:
Amplifier
| Size: 4 MB
Table of Contents
Table of Contents
3
List of Figures
6
List of Tables
8
Section 1: General Information
9
Specifications
9
Safety Considerations
10
High Voltage Hazards
10
High Current Hazards
10
RF Transmission Hazards
11
Electrical Discharge Hazards
11
High Leakage Current
11
Shipment
10
1 Introduction
9
Description
9
Equipment Supplied
9
Inspection
9
Section 2: Description of Unit
13
2 Introduction
13
Description of Unit
13
Figure 2-1: Outline Drawing, Ku-Band H-Series High Power Outdoor SSPA
13
Installation of Unit
14
Connectors
15
Figure 2-2: Connectors at Bottom of Enclosure
15
Figure 2-3: RF Output Connector at Top of Enclosure
15
M&C Connector (J4) [MS3112E18-32S]
16
RF Input Port (J1) [Type N (F)]
16
RF Output (J2)
16
RF Output Sample Port (J3) [Type N (F)]
16
Table 2-1: Monitor & Control Connector (J4) Pin-Outs
17
AC Input Connector (J7) [MS3102E20-19P]
18
Power Cable Construction
18
Table 2-2: Link Port (J5) Pin-Outs
18
Table 2-3 Switch Port (J6) Pin-Outs
18
Table 2-4: AC Input Connector (J7) Pin-Outs
18
Link Port (J5) [MS3112E10-6S]
18
Switch Port (J6) [MS3112E10-6S]
18
AUX PWR Port (J8) [MS3112E10-6S]
19
Handheld Connector (J10) [MS3112E12-8S]
19
Table 2-5: AUX PWR Port (J8) Pin-Outs
19
Table 2-6: Handheld Connector (J10) Pin-Outs
19
Chassis Ground Terminal
20
RF Input Sample Port (Optional) [Type N (F)]
20
Physical Features
20
Summary Alarm Indicator
20
Airflow and Removable Fan Trays
20
Waveguide Pressure Window (Option)
20
Section 3: Quick Start and Operation
21
3 Introduction
21
Figure 3-1: Ethernet Quick Start Cable, 207755
21
Figure 3-2: RS-232 Quick Start Cable, 207998
21
Quick Start Cables
21
Quick Start Connections
22
Quick Start Ethernet Connection
22
Set PC Configuration
22
Operations Manual, High Power Outdoor SSPA 211670 REV D
23
Quick Start RS-232 Connection
23
Setting Custom IP Address
24
Figure 3-3: Universal M&C Add Unit Menu
25
Figure 3-4: Add Compact Outdoor SSPA Window, Via Serial (Left) or Internet (Right)
25
Universal M&C Status Window
26
Signal Indicators
26
Figure 3-5: Universal M&C Status Window
26
Fault Status Indicators
27
Figure 3-6: Fault Indicators
27
Voltage, Current and Temperature Display
28
Gain Adjustment
28
Forward and Reflected RF Power Indicators
28
Figure 3-7: Universal M&C Settings Window
29
Universal M&C Settings Window
29
Figure 3-8: Spare Fault Wizard
30
Figure 3-9: Universal M&C IP Setup Window
31
IP Setup Window
31
Figure 3-10: Preferences Window
32
Figure 3-11: Example, Log Entry
32
Universal M&C Preferences
32
Universal M&C Operation
25
Figure 3-12: Enter IP Address for Amplifier (Default Is 192.168.0.9)
33
Figure 3-13: M&C Applet Loading into Browser Window
33
Figure 3-14: Enter Password (Default Is "Paradise")
34
Figure 3-15: Status and Faults Window Descriptions
34
Navigating the Web M&C
34
Figure 3-16: Communication Settings Window Descriptions
35
Figure 3-17: General Settings Window Descriptions
36
Figure 3-18: Fault Settings Window Descriptions
37
Web-Based M&C
33
Section 4: L Band Operation
39
4 Block up Converter Overview
39
Figure 4-1: Configuration Matrix, High Power Outdoor SSPA, BUC Options
39
Figure 4-2: High Power Outdoor Block Diagram of BUC / SSPA System
40
Table 4-1: ZBUC Converter Frequency Specifications
40
ZBUC Features
40
Smart Reference Technology
41
Table 4-2: ZBUC RF Output Phase Noise Specification
41
ZBUC Converter Theory of Operation
41
ZBUC FSK Monitor and Control
42
Figure 4-3: High Power Outdoor SSPB with Q-Series Q-Flex Modem
43
IFL Cable Considerations
43
Table 4-3: Common Coaxial Cable Characteristics
43
Typical System Configuration
43
Section 5: Redundant System Operation
45
5 Redundant System Concepts
45
Figure 5-1: Standard 1:1 Redundant System with Input/Output Switches
45
Figure 5-2: 1:1 Redundant System with Input Splitter Substituted for Input Switch
45
Figure 5-3: 1:1 Redundant System with L Band Input
46
Figure 5-4: Outline Drawing, 1:1 Redundant High Power Outdoor System
47
Figure 5-5: Schematic, 1:1 Redundant High Power Outdoor System
48
Hardware Setup
48
Software Setup
49
Stand-Alone 1:1 Redundant System
49
Figure 5-6: 1:1 System with RS-232 Communication to each Amplifier
49
Figure 5-7: M&C Program "SSPA Settings" Window
50
PC Control Using RS232 and Paradise M&C Software
52
Figure 5-8: Adding a SSPA Monitor and Control Window
52
Figure 5-9: Add New Compact Outdoor SSPA Window
53
Figure 5-10: Individual SSPA Operation Window
53
Figure 5-11: Universal M&C, Add Unit Menu Tree
53
Figure 5-12: Universal M&C, Add 1:1 Redundant System Window
54
Figure 5-13: Universal M&C, Showing a Configured 1:1 Redundant System
54
Figure 5-14: Dialog Window, Affirm Mute of Online Amplifier
55
Figure 5-15: Control Panel Showing Unit 1 Faulted and Signal Routed to Unit 2
56
Figure 5-16: Unit1 Status Panel Showing Summary and Temperature Faults
56
PC Control Using RS-485 and Paradise M&C Software
57
Figure 5-17: 1:1 Redundant System with RS-485 Full Duplex Communication
57
Figure 5-18: 1:1 Redundant System with Half Duplex Communication
58
High Power Outdoor Amplifier in 1:1 Redundancy
47
Figure 5-19: Block Diagram, 1:2 Redundant System
59
Hardware Setup
60
Software Setup
60
PC Control Using Universal M&C Software
61
Figure 5-20: Universal M&C Application, Add Unit Screen
61
Figure 5-21: Universal M&C Application, Add High Power Outdoor SSPA
61
Figure 5-22: Universal M&C, High Power Outdoor SSPA Status Window
62
Figure 5-23: Universal M&C Application, Add Controller
62
Figure 5-24: Universal M&C Application, Controller Status Window
63
High Power Outdoor SSPA in 1:2 Redundant Systems
59
Section 6: Phase Combined Systems
65
6 Phase Combining Overview
65
Figure 6-1: Phase Combined Amplifier System
65
Figure 6-2: 1:1 Fixed Phase Combined System with FPRC-1100 Controller
66
1:1 Fixed Phase Combined Systems
67
Figure 6-3: FPRC-1100 Phase Combined System Controller
67
1:2 Fixed Phase Combined Systems
68
Figure 6-4: Block Diagram, 1:2 Fixed Phase Combined System
68
Section 7: Maintenance and Troubleshooting
69
7 Introduction
69
Cooling System Maintenance
69
Fan Removal and Heatsink Cleaning
69
Fan Replacement
70
Troubleshooting Guide
72
Unit Doesn't Power up
72
Unit Powers On, LED Lamp Blinks (Red or Green)
72
Unit Powers On, LED Lamp Glows Red
72
SSPA Unit Powers Up, LED Lamp Glows Green, no RF Present
72
Cannot Connect to SSPA through Remote Control Interface
73
The FSK Link between a Modem and the SSPB Unit Is Not Working
73
Section 8: Remote Control Interface
75
8 Serial Protocol Overview
75
Figure 8-1: Amplifier Remote Control Interface Stack
75
Table 8-1: Interface Selection
76
Table 8-2: Unique Network Address Hardware Select
76
Serial Communication
78
Header Packet
78
Frame Sync Word
78
Destination Address
78
Figure 8-2: Basic Communication Packet
78
Figure 8-3: Header Sub-Packet
78
Source Address
79
Data Packet
79
Protocol ID
79
Request ID
79
Command
79
Figure 8-4: Data Sub-Packet
79
Data Tag
80
Table 8-3: Command Byte Values
80
Table 8-4: Data Tag Byte Values
80
Data Address / Error Status / Local Port Frame Length
81
Data Length
81
Data Field
81
Table 8-5: Error Status Bytes
81
Trailer Packet
82
Frame Check
82
Timing Issues
82
Serial Communications Protocol
83
Table 8-6: Request Frame Structure
83
Table 8-7: Response Frame Structure
83
Table 8-8: System Settings Data Values
84
Table 8-9: System Threshold Data Values
85
Table 8-10: System Condition Addressing
86
Ethernet Interface
87
Ipnet Interface
87
General Concept
87
Figure 8-6: UDP Redirect Frame Example
88
Table 8-11: OSI Model for SSPA Ethernet IP Interface
88
Setting Ipnet Interface
89
Troubleshooting IP Connectivity
89
Overview
87
SNMP Interface
90
SNMP MIB Tree
91
Description of MIB Entities
92
Extended SNMP
93
Extended SNMP MIB Tree
94
Extended SNMP MIB Tree Elements in Detail
96
Table 8-12: Detailed Settings for CO SSPA Mode (Device Type=2)
97
Table 8-13: Detailed Thresholds
98
Table 8-14: Detailed Conditions
99
Figure 8-7: Universal M&C, IP Setup Tab
100
Figure 8-8: Universal M&C, Settings Tab
100
Connecting to a MIB Browser
101
Figure 8-10: Getif Mbrowser Window, with Update Data in Output Data Box
101
Figure 8-9: Getif Application Parameters Tab
101
SNMP V3 Implementation Issues in Sspas
102
M&C Via SNMP
100
Section 9: Option, Universal Handheld Controller
105
9 Overview, RCH-1000
105
Figure 9-1: Universal Handheld Controller (RCH-1000)
105
Figure 9-2: Communication Cable (L212640-2) for High Power Outdoor Sspas
105
Appendix A: Installation, Uni-Strut Frame for 1:1 Redundant System Mounting
107
Table A-1: Parts List, Mounting Kit Assembly (L213302-1)
108
Figure A-1: Uni-Strut Assembly
109
Figure A-2: Uni-Strut Assembly, Hardware Placement
110
Figure A-3: Uni-Strut Assembly, Base Strut
110
Figure A-4: Mount Hpas to Frame
111
Figure A-5: Components, Waveguide Switch Array
112
Figure A-6: Mounting Switch Support to Frame
112
Figure A-7: Connect Waveguide to Switch, Ku-Band (Typical)
113
Figure A-8: Switch Assembly Installation, Ku-Band (Typical)
113
Figure A-9: Waveguide Installation, Ku-Band (Typical)
114
Figure A-10: Input Plate Assembly (with Splitter)
115
Figure A-11: Mount Input Plate Assembly to Frame
115
Figure A-12: Connect Switch and Link Cables
116
Appendix B: Installation, Uni-Strut Frame for 1:2 Phase Combined System
117
Table B-1: Parts List, Mounting Kit Assembly (L214792-1)
118
Figure B-1: Uni-Strut Assembly
119
Figure B-2: Uni-Strut Assembly, Hardware Placement
120
Figure B-3: Uni-Strut Assembly, Attach Footers
120
Figure B-4: Install Amplifiers
121
Figure B-5: Install Signal Box
122
Figure B-6: Components, Output Waveguide and Switch Array
123
Figure B-7: Attach W/G Segment 214784-1 to SW2
124
Figure B-8: Attach W/G Segment 214787-1, SW1 and W/G Segment 214783-1
124
Figure B-10: Attach W/G Assembly to Signal Box Support Brackets
125
Figure B-9: Attach W/G Segment 214785-1, Magic Tee and W/G 214786-1
125
Figure B-11: Attach Magic Tee Support Bracket to Uni-Strut Frame
126
Figure B-12: Attach W/G Segment 214782-1 to SW1
126
Figure B-13: Insert O-Ring Gasket at HPA RF Output and Secure Waveguide
127
Figure B-14: Semi-Rigid Coaxial Cables
128
Figure B-15: Connect W5 to SW2 (Shown from Top of Switch)
129
Figure B-16: Connect W4 to Port J8
129
Figure B-17: Connect W4 to Diode/Attenuator at Crossguide Coupler
129
Figure B-18: Connect W1 to Signal Box Port J4 (HPA1) and SW2-2
130
Figure B-19: Connect W2 to Signal Box Port J2 (HPA2)
130
Figure B-20: Connect W3 to Signal Box Port J3 (HPA3)
130
Figure B-21: System Control Cable
131
Figure B-22: Schematic, Connections for 1:1 BUC and 1:2 HPA System Cables
132
Documentation
133
Advertisement
Advertisement
Related Products
Teledyne HPAC-3300
Teledyne HPAC-2005
Teledyne DALSA HS-40-04k40-xx-R
Teledyne DALSA HS-80-08k80-xx-R
Teledyne DALSA HS-82-04k80-xx-R
Teledyne DALSA Piranha HS-80-08k40
Teledyne DALSA Piranha HS-80-08k80
Teledyne DALSA Piranha HS-82-04k80
Teledyne DALSA Piranha HS-80-04k40
Teledyne HS-80-08k80-00-R
Teledyne Categories
Measuring Instruments
Analytical Instruments
Test Equipment
Digital Camera
Laboratory Equipment
More Teledyne Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL