Table A-5 Environmental Specifications - Sun Microsystems Ultra 2 series Service Manual

Hide thumbs Also See for Ultra 2 series:
Table of Contents

Advertisement

A
A.2 Environmental Specifications
Environmental
Temperature:
System without removable
tape media
System with removable tape
media
Humidity
Altitude:
System without removable
tape media
System with removable tape
media
Maximum dwells at extremes
Shock
Vibration
Acoustic noise
A-4
Table A-5 lists operating and non-operating environmental specifications for
the system unit and server.

Table A-5 Environmental Specifications

Operating
50 to 104°F (10 to 40°C), 16-hour dwells
at extremes
50 to 95°F (10 to 35°C), 16-hour dwells
at extremes
20 to 80% noncondensing at 104 °F
(40°C), 16-hour dwells at extremes
9,842.5 feet (3,000 meters) at 50 to
98.6°F (10 to 37°C), 2-hour dwells at
extremes, to 104°F (40°C) at sea level
9,842.5 feet (3,000 meters) at 50 to
89.6°F (10 to 32°C), 2-hour dwells at
extremes, to 95°F (35°C) at sea level
16 hours
2.0 G peak for 11 ms, 3 shocks per face
0.1 G peak, 3 mutually perpendicular
axes, 5-500-5 Hz sweep
5.4 bels
Ultra 2 Series Service Manual—May 1996
Non-Operating
-4 to 131°F (-20 to 55°C), 16-hour dwells
at extremes
-4 to 131°F (-20 to 55°C), 16-hour dwells
at extremes
95% noncondensing at 104°F (40°C)
16-hour dwells at extremes
40,000 feet (12,192 meters) at 32°F (0°C),
2-hour dwells at extremes
40,000 feet (12,192 meters) at 32°F (0°C),
2-hour dwells at extremes
16 hours
15 G peak for 11 ms, 3 shocks per face
0.5 G peak, 3 mutually perpendicular
axes, 5-500-5 Hz sweep
5.2 bels (idle)