Heat&Glo MEZZO-1000-AU Installation Manual

Heat&glo mezzo-1000-au; mezzo-1300-au; mezzo-1300st-au; mezzo-1600-au fireplace insert
Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OwNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
NOTE: NOT INTENDED FOR
FIREPLACE INSERT.
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE wHILE IT IS IN OPERATION.
DO NOT MODIFY THIS APPLIANCE.
Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15
Installation Manual
Installation and Appliance Setup
Ref No: GMK10222
AS4553:
wARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEZZO-1000-AU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heat&Glo MEZZO-1000-AU

  • Page 1 DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE wHILE IT IS IN OPERATION. DO NOT MODIFY THIS APPLIANCE. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 2: Table Of Contents

    B. Accessories ........57  = Contains updated information. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 3: Installation Standard Work Checklist

    Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2304-972 Rev. B 2/15 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 4: Product Specific And Important Safety Information

    (1.61 mm) (3.15 mm) (1.85 mm) (3.57 mm) (1.93 mm) .023 in. .010 in. .023 in. .010 in. .023 in. .010 in. Pilot Injector (.584 mm) (.254 mm) (.584 mm) (.254 mm) (.584 mm) (.254 mm) NOTE: The gas control valve supplied with this product is approved for a maximum inlet pressure of 3.40 kPa. For pressures over 3.40 kPa, an in line pressure regulator must be installed upstream from the gas control valve. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 5: High Altitude Installations

    Vertical Tube Furnace at 750 ºC (1382 °F) and UL763 shall be considered non-combustible materials. F. Combustible Materials Specification Materials made of or surfaced with wood, compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials. G. Electrical Codes All electrical safety testing has been done following the EN 60335-2-102 standard. Local codes apply. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 6: Getting Started

    Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 7: Framing And Clearances

    2-3/8 8-9/16 8-9/16 8-9/16 8-9/16 1575 1575 24-1/2 24-1/2 8-9/16 8-9/16 7-1/4 7-1/4 8-7/8 8-7/8 48-3/16 1224 1524 2-3/4 2-3/4 23-3/4 23-3/4 Figure 3.1 Appliance Dimensions - MEZZO-1000-AU, MEZZO-1300-AU  Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 8 Inches Millimeters 17-1/8 1880 63-1/8 1603 18-5/8 15-5/8 47-3/4 1213 48-1/2 1232 2-3/8 8-9/16 8-9/16 24-1/2 1575 7-1/4 8-9/16 8-7/8 2-3/4 1829 23-3/4 Figure 3.2 Appliance Dimensions - MEZZO-1600-AU Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 9 Millimeters 17-1/8 1575 51-1/8 1299 18-1/8 15-5/8 41-3/4 1060 42-1/2 1080 2-3/8 8-9/16 8-9/16 24-1/2 1575 7-1/4 8-9/16 8-7/8 2-3/4 1524 23-3/4 Figure 3.3 Appliance Dimensions - MEZZO-1300ST-AU  Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 10 Inches Millimeters Inches Millimeters 1295 1600 16-3/4 16-3/4 16-3/4 13-1/8 13-1/8 13-1/8 37-3/16 49-3/16 1249 61-3/16 1554 40-5/16 1024 52-5/16 1329 64-5/16 1634 Figure 3.4 Clean Face Trim Front (Inside Fit) Decorative Front Dimensions Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 11: Clearances To Combustibles

    28-1/2 18-3/4 MEZZO-1300-AU 10, Figure Millimeters 1797 1530 2550 10.14 and Inches 79-1/2 72-1/4 112-3/8 10.15. 31-3/4 18-3/4 MEZZO-1600-AU Millimeters 1835 2013 2854 Figure 3.5 Appliance Locations: MEZZO-AU Single-Sided Models  Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 12: Constructing The Appliance Chase

    The chase should not break the outside building supported by framing materials and the ceiling clearances are maintained. envelope in any manner. Walls, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infiltration may be an issue, the inside surfaces may be sheetrocked and taped (or an equivalent method may be used) to achieve maximum air tightness. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 13: Minimum Framing Dimensions

    Floor Flooring Appliance Appliance Appliance to Ceiling (Vent Pipe) (Height) (Depth) (Width) Inches 18-1/4 72-1/4 55-1/2 Millimeters 1219 1835 1219 1410 * = Adjust framing dimensions for interior sheathing (such as sheetrock) **= Header depth not to exceed 3-1/2 in. (89 mm). ***= If appliance is installed off of floor, maintain required clearances to combustibles. Construct platform in accordance with local building codes. Figure 3.7 Clearances to Combustibles MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1600-AU Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 14 Rear of to Ceiling Floor Flooring Appliance to Ceiling (Vent Pipe) (Height) (Depth) (Width) Appliance 60-1/4 55-1/2 MEZZO- 1300ST-AU 1067 1530 1219 1410 * = Adjust framing dimensions for interior sheathing (such as sheetrock) **= Header depth not to exceed 3-1/2 in. (89 mm). ***= If appliance is installed off of floor, maintain required clearances to combustibles. Construct platform in accordance with local building codes. Figure 3.8 Clearances to Combustibles - MEZZO-1300ST-AU Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 15: Floor Protection

    • Insulation and other materials must be secured to prevent accidental contact. • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace could cause overheating and fire. Figure 3.9 Floor Protection Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 16: Termination Location And Vent Information

    39.8°-42.5° ............ 9 90 42.5°-45.0° ............1 2 20 45.0°-49.4° ............1 5 20 49.4°-53.1° ............1 8 30 53.1°-56.3° ............2 1 30 56.3°-59.0° ............2 2 90 59.0°-60.3° ............2 4 40 *910 mm minimum in snow regions Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 17: Chimney Diagram

    2. Prohibited area below electricity meter or fuse box extends to ground level. 3. See clause 5.13.6.6 for restrictions on a flue terminal under a roofed area. 4. See Appendix J, Figure J1(a) and J2(a) for clearances required from a flue terminal to a LP Gas cylinder. A flue terminal is considered to be a source of ignition. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 4.3 Minimum Clearances for Termination Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 18: Approved Pipe

    Horizontal NOTICE: Before painting, contact your dealer for Figure 4.4 information on the appropriate high temperature paint. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 19: Vent Diagrams

    • Horizontal runs of vent do not require vertical rise; horizontal runs may be level. • Horizontal termination cap should have a 1/4 in. (6mm) downward slant to allow any moisture in cap to be BREAK released. HERE Figure 4.6 Break the Exhaust Restrictor Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 20 4.6 m 7 ft. 2.1 m 18 ft. 5.5 m 7 ft. 2.1 m 18 ft. 5.5 m 8 ft. 2.4 m 21 ft. 6.4 m 8 ft. 2.4 m 21 ft. 6.4 m + H = 63 ft. (19.2 m) Maximum + H = 63 ft. (19.2 m) Maximum = 40 ft. (12.2 m) Maximum = 40 ft. (12.2 m) Maximum Figure 4.9 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 21 5.5 m 7 ft. 2.1 m 18 ft. 5.5 m 8 ft. 2.4 m 21 ft. 6.4 m 8 ft. 2.4 m 21 ft. 6.4 m + H = 63 ft. (19.2 m) Maximum + H = 63 ft. (19.2 m) Maximum + H = 40 ft. (12.2 m) Maximum + H = 40 ft. (12.2 m) Maximum INSTALLED HORIZONTALLY Figure 4.10 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 22 2.1 m 18 ft. 5.5 m 7 ft. 2.1 m 18 ft. 5.5 m 8 ft. 2.4 m 21 ft. 6.4 m 8 ft. 2.4 m 21 ft. 6.4 m + H = 63 ft. (19.2 m) Maximum + H = 63 ft. (19.2 m) Maximum + H = 40 ft. (12.2 m) Maximum + H = 40 ft. (12.2 m) Maximum Figure 4.11 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 23 Top Vent - Vertical Termination No Elbows V = 3 ft Min. (1m), 50 ft. Max. (15.2 m) Note: If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed. Note: Use DVP Series components only. Figure 4.12 Vertical Vent Maximum Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 24 Minimum H Maximum 2 ft. 610 mm 4 ft. 1.2 m 3 ft. 914 mm 9 ft. 2.7 m 4 ft. 1.2 m 12 ft. 3.6 m 5 ft. 1.5 m 15 ft. 4.5 m + H = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Total Figure 4.13 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 25 Minimum Maximum 2 ft. 610 mm 4 ft. 1.2 m 3 ft. 914 mm 9 ft. 2.7 m 4 ft. 1.2 m 12 ft. 3.6 m 5 ft. 1.5 m 15 ft. 4.5 m + V = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum INSTALLED HORIZONTALLY Figure 4.14 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 26: Vent Clearances And Framing

    Firestop OTHER MATERIAL WALL 12 in. Figure 5.1 Horizontal Venting Clearances To Combustible 10 in. Materials MODEL MEZZO-1000-AU 63 in. 62 in. MEZZO-1300-AU MEZZO-1300ST-AU 1.60 m 1.57 m MEZZO-1600-AU * Shows center of vent framing hole for top venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 5.2 Wall Penetration Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 27: Install The Ceiling Firestop

    Figure 5.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 28: Installing The Heat-Zone ® Kit

    • Determine the location for the air register/fan housing assembly. Reference the Heat-Zone Kit instructions for the ® remaining installation steps. HEAT ZONE LOCATION ® LEFT AND RIGHT SIDES HEAT ZONE ® ADAPTER BOX Figure 5.5 Heat Zone Adapter Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 29: Appliance Preparation

    24 in. (610 mm) of vertical venting before attaching any elbow to the appliance. BOTTOM PANEL SCREW LOCATIONS 3. Place the 1/8 in. (3 mm) thick, square fiberglass gasket over the initial 24 in. (610 mm) vent section. 4. Place the fiberglass rope ring over the gasket. Ensure Figure 6.1 Location of Fiberglass Rope Ring both the gasket and the rope ring are seated on the top of the appliance. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 30: Securing And Leveling The Appliance

    • Secure the appliance to the framing by using nails or screws through the nailing tabs. Some figures in manual show the fireplace installed on the floor. However, this fireplace can be elevated off the floor SHIPPING provided that the fireplace is properly supported by framing FLANGE materials and the ceiling clearances are maintained. Figure 6.4 Nailing Tabs Figure 6.3 Nailing Tabs Installation Position Shipping Position NAILING TABS BOTH SIDES Figure 6.2 Nailing Tab Locations Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 31: Venting And Chimneys

    • Lightly tug on the pipe to confirm the tabs have locked. It is acceptable to use screws no longer than 1/2 in. (13 mm) to hold outer pipe sections together. If predrilling holes, DO NOT penetrate inner pipe. For 90º and 45º elbows that are changing the vent direction from horizontal to vertical, one screw minimum should be put in the outer flue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Figure 7.4 Seams Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 32: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 33: Disassemble Vent Sections

    D. Disassemble Vent Sections • Rotate either section (see Figure 7.9) so the seams on both pipe sections are aligned as shown in Figure 7.10 • Pull carefully to separate the pieces of pipe. Figure 7.9 Rotate Seams for Disassembly Figure 7.10 Align and Disassemble Vent Sections Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 34: Vertical Termination Requirements

    NOTICE: Failure to properly caulk the roof flashing and pipe seams could permit entry of water. • Caulk the gap between the roof flashing and the outside diameter of the pipe. • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 35: Horizontal Termination Requirements

    1-1/2 in. (38 mm) overlap between heat shields. • Attach the extended heat shield to either of the existing heat shields using the screws supplied with the extended heat shield. Refer to vent components diagrams in the Figure 7.14 back of this manual. • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be field constructed. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 36 1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 7.15 Venting Through the Wall Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 37: Electrical Information

    2. Remove screws on left and right sides of component heat shield and lift it out of the control cavity. JUNCTION CORD LED POwER SUPPLY Figure 8.3. Valve Cavity (Lower Access Panel Removed) Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 38: Wiring Requirements

    (220/240V) FLAME MODULATION Heat Zone CORD ADAPTER BLACK BROWN ORANGE GREEN (PILOT) (MAIN) GROUND LED CONTROL BATTERY PACK 6V DC LED LIGHT TRAY Figure 8.4 IntelliFire™ Plus Wiring Diagram with Remote Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 39: Gas Information

    3. Unplug the 6V transformer from the junction cord. Figure 9.1. Valve Pressure Taps. This will turn the power off to the appliance. wARNING Fire Risk. Explosion Hazard. High pressure will damage valve. • Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig. • Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 40 Figure 9.4. 11. Remove light tray from appliance by lifting up and out through the bottom glass opening. PILOT SHIELD MEDIA TRAY GAS VALVE GAS ACCESS Figure 9.5. Gas Fitting Access with Vanity Panel Removed BURNER ASSEMBLY 4836 & 6048 BURNER ASSEMBLY 7260 & 8472 Figure 9.3. Media Tray with Burner and Pilot Shield Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 41: Gas Connection

    Fittings and connections could have loos- ened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 42: Air Shutter Setting

    MEZZO-1600-AU ULPG Standard Standard GLASS REFRACTORY Opening= Opening= 3/8 in. (10 mm) Full Open LOG KIT 3/8 in. (10 mm) Full Open DETAIL Figure 9.6 Air Shutter Location Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 43: Finishing

    Vertical Tube Furnace at 750 ºC. WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Inadequate air space could cause overheating and fire. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 44 TEMPLATE adjacent to the fireplace opening. Tape wall board joints around the fireplace opening with fiberglass-mesh tape. It will provide a more crack-resis- tant joint than paper tape. Fill, smooth and finish wall joints with chemically setting-type joint compound. It will provide a more crack-resistant joint than air-drying light- Figure 10.2 Finishing and Facing Materials - Single-sided Models weight compound. Painting If desired finishing includes a painted wall, 100% acrylic latex with compatible primer is recommended around this appliance. Oil-based or standard acrylic paints may dis- color due to heat exposure. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 45 Decorative facing material thickness is measured from the face of the factory-installed non-combustible board. See Figure 10.2 and Figure 10.3. The front for this appliance are compatible with non-com- bustible materials. See Figure 10.2 and Figure 10.3. Refer to Section 1.E and 1.F of this manual for definitions and qualifications of non-combustible and combustible materials. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 46 • Over heating and fire could occur. TRIM RING INSTALLED Figure 10.4 Non-Combustible Finish Material Diagram for 1 - 4 in. (25 - 102 mm) Thick Inside Fit Method Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 47 39-1/8 in. (994 mm) MEZZO-1000-AU 51-1/8 in. (1299 mm) MEZZO-1300-AU, MEZZO-1300ST-AU 63-1/8 in. (1603 mm) MEZZO-1600-AU 15-3/4 in. FIREPLACE VIEWING AREA (400 mm)  Figure 10.6 Finished Opening Dimensions - Inside Fit Method Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 48: Mantel And Wall Projections

    = 24-1/2 in. (622 mm) Figure 10.7 Minimum Vertical and Maximum Horizontal  Dimensions of Combustibles - MEZZO-1000-AU Figure 10.8 Minimum Vertical and Maximum Horizontal  MEZZO-1300-AU, MEZZO-1300ST-AU Dimensions of Combustibles - MEZZO-1600-AU Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 49: Decorative Front Dimensions For Finishing

    Note: See appliance Owner’s Manual for TV mounting guidelines. FIREPLACE OPENING See Appliance Dimension Diagram-Dimension B Figure 3.1 (MEZZO-1000-AU, MEZZO-1300-AU) Figure 3.2 (MEZZO-1600-AU) Figure 3.3 (MEZZO-1300ST-AU) Figure 10.10 Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 50: Appliance Setup

    Use two self-drilling screws to secure the bracket to the firebox side. See Figure 11.4. Repeat for right side panel. BOTTOM RETAINING LIP Figure 11.1 Fixed Glass Assembly *Back panel used in single-sided models B. Remove the Shipping Materials Remove shipping materials from inside or underneath Figure 11.2 Placement of Glass Panels the firebox. Verify all components are with the fireplace. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 51: Install Media

    (13 mm) pieces near pilot. RETAINING BRACKET DETAIL Figure 11.5 Selecting Flat Media for Pilot Cover. RETAINING BRACKET LOCATION 2. The included media placement jig, shown in Figure 2, MUST be used any time media are placed on the burner to ensure that none end up in the burner lighting area. Verify that the media placement jig is correctly Figure 11.4 Retaining Bracket Installation - See-Through Models installed in place in the appliance. See Figure 11.7. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 52 3. The media placement jig must remain in place while WARNING! Risk of Fire. DO NOT place media directly in media is placed on the media tray and around the pilot front of the pilot assembly. bracket. MEDIA PLACEMENT JIG Figure 11.7 Media Placement Jig in Place Figure 11.9 Remove Media Placement Jig Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 53: Install Log Set

    10. Install bottom glass trim between glass and glass with the installed control. If a wall switch is installed, refer frame. See Figure 8. to the instructions included with the control. LED Lighting The ON/OFF function for the LED lighting option is controlled by the IntelliFire™ Plus remote control. Follow instructions included with the installed control to test the LED lighting. Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 54: Reference Materials

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 12.1 DVP Vent Components Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 55 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT FireBrickTermination Cap Figure 12.2 DVP Vent Components Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 56 13-1/4 in. (367 mm) 14 in. 27-1/2 in. 24-5/8 in. (356 mm) (127 mm) (625 mm) DRC-RADIUS RF6M Cap Shield Roof Flashing Multi-pak Figure 12.3 DVP Vent Components Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...
  • Page 57: Accessories

    • Keep remote controls out of reach of children. Contact your dealer if you have questions. Heat-Zone ® Follow the instruction supplied with the kit for operation. • Preparation for installation of Heat-Zone Kit is discussed ® in Section 5.E. Contact your dealer if you have questions. Heat & Glo, a brand of Hearth & Home Technologies 7571 215 Street West, Lakeville, MN 55044 www.heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2015 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15...

This manual is also suitable for:

Mezzo-1300-auMezzo-1300st-auMezzo-1600-au