FIREBRICK REPLACEMENT

The firebricks fitted to the Rayburn 345W are of first
quality manufacture, and providing the cooker has been
installed and used correctly will have a reasonable life.
They are, however, expendable items and in time will
require renewal.
Replacement bricks either in sets or singly can be
obtained from your Rayburn distributor. Always quote the
manufacturing number.
The manufacturing number, which will be found fixed to
the appliance, should be quoted if any question arises in
connection with the Rayburn 345W Cooker.

HOT WATER SERVICE

The cooker has been designed to provide a satisfactory
supply of domestic hot water with or without a limited
amount of heating with a normal day's cooking providing
the cooker is kept alight overnight and the system
complete with lagged cylinder conforms to the installation
instructions.

SERVICING

Always use a qualified service/heating engineer when
servicing is required. Use only authorised replacement
parts. Do not make unauthorised modifications.
Any air inlet grilles must be maintained so that they are
free from blockage.
Failing to maintain your cooker properly can lead to a
chimney fire. Chimney fires occur when combustible
deposits on the inner walls of the chimney ignite. These
combustible deposits, called "creosote", are a natural by-
product of wood burning. A fire hazard exists if 1/4" of
creosote (or more) coats the inner walls of the chimney.

FUME EMISSION WARNING

Properly installed and operated, this cooker will not emit
fumes.
Occasional fumes from de-ashing and re-fuelling may occur
but persistent fume emission must not be tolerated.
If fume emission does persist, then the following immediate
action should be taken:-
a) Open doors and windows to ventilate room.
b) Let the fire out or remove lit fuel from cooker.
c) Check for flue or chimney blockage, and clean if
required.
d) Do not attempt to relight fire until cause of fumes has
been identified, and if necessary, seek professional
advice

SPARES LIST

Part Number
Description
QWX
Boiler Thermostat
1/16182 T
Bottomgrate bars top
1/16182 B
Bottomgrate bars bottom
3/16272
Oven side firebricks
4/16273
Firebox side top firebricks
3/16271
Front firebrick
3/16274
Removable boiler face
rear firebrick
3/16275
Removable boiler face
side firebrick
3/18172
Grate Baffle
Replacement parts if required are always available ex-
works. Write to us should any difficulty be encountered in
obtaining them from your usual supplier.
SMOKE/SMELL EMITTED DURING INITIAL USAGE
Some parts of the cooker have been coated with a light
covering of protective oil. During initial operation of the
cooker, this may cause smoke/smell to be emitted and is
normal and not a fault with the appliance, it is therefore
advisable to open doors and or windows to allow for
ventilation.
Lift the insulating lids to prevent staining the linings.
8
No Reqd
1
5
5
2
1
1
1
2
2

Advertisement